Evidence map›Paper›PMID 39899500›Full record

ArticlePloS one2025

Investigation of customized total knee implant with articular cartilage under loading conditions using finite element analysis.

Shady A Alshewaier, Mohamed Yacin Sikkandar, Ali Ahmed Ali Almakrami, S Sabarunisha Begum, Ahmad Alassaf, Ibrahim AlMohimeed, S Meenatchi Sundaram, Dheeraj Poojary, Natteri M Sudharsan, Eddie Y K Ng

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Shady A AlshewaierDepartment of Physical Therapy‬, College of Applied Medical Sciences‬, Majmaah University, Al Majmaah, Saudi Arabia.
Mohamed Yacin SikkandarDepartment of Medical Equipment Technology, College of Applied Medical Sciences, Majmaah University, Al Majmaah, Saudi Arabia.ORCID 0000-0002-7971-1504
Ali Ahmed Ali AlmakramiDepartment of Medical Equipment Technology, College of Applied Medical Sciences, Majmaah University, Al Majmaah, Saudi Arabia.
S Sabarunisha BegumDepartment of Biotechnology, P.S.R. Engineering College, Sivakasi, India.ORCID 0000-0002-8954-6004
Ahmad AlassafDepartment of Medical Equipment Technology, College of Applied Medical Sciences, Majmaah University, Al Majmaah, Saudi Arabia.
Ibrahim AlMohimeedDepartment of Medical Equipment Technology, College of Applied Medical Sciences, Majmaah University, Al Majmaah, Saudi Arabia.
S Meenatchi SundaramDepartment of Instrumentation and Control Engineering, Manipal Institute of Technology, Manipal, India.
Dheeraj PoojaryMachine Design, NMAM Institute of Technology Nitte, Udupi, India.
Natteri M SudharsanDepartment of Mechanical Engineering, Rajalakshmi Engineering College, Chennai, India.ORCID 0000-0003-2362-8741
Eddie Y K NgSchool of Mechanical & Aerospace Engineering, College of Engineering, Nanyang Technological University, Singapore, Singapore.ORCID 0000-0002-5701-1080

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Knee osteoarthritis (KOA) is a degenerative joint disease predominantly affecting the elderly and is often managed through knee replacement surgeries. West Asians, who frequently engage in activities involving bending and kneeling during their prayers, tend to exhibit distinct bone anatomy compared to the Caucasian population. This research posits that patient-specific, customized knee implants with articular cartilages may lead to reduced post-surgical discomfort and a better implant fit compared to conventional standard implants. This study presents a novel concept and approach for the development of a customized total knee implant with articular cartilages, specifically tailored to simulate loading conditions using finite element analysis (FEA) for the Saudi Arabian population. The research analyses patient-specific customized knee implants with articular cartilages under both pre- and post-implant conditions using a finite element model (FEM). Computed tomography (CT) images of patients were utilized to create a solid model, which was then analysed under various constraints and conditions. The meshing process employed tetrahedral elements, converging with 76,197 nodes and 43,009 elements. The analysis was conducted under different body weights, specifically 75-80 kg and 100-105 kg. Two sets of force and moment were applied: the first with a force of 1000 N and a moment of 1.5 N-m, and the second with a force of 750 N and a moment of 0.8 N-m. The results indicated a 5% reduction in stress with implants designed for a 100 kg body weight, along with a significant reduction in ligament strain when compared to conventional knee joint stresses. This study offers a promising pathway toward reducing post-surgical discomfort. The proposed innovative solution has the potential to revolutionize total knee implant technology, offering enhanced functionality and improved patient outcomes for the Saudi Arabian population.

Indexed as

Arthroplasty, Replacement, KneeCartilage, ArticularFinite Element AnalysisKnee JointKnee ProsthesisBiomechanical PhenomenaFemaleHumansMaleMiddle AgedOsteoarthritis, KneeProsthesis DesignTomography, X-Ray ComputedWeight-Bearing

Identifiers

PMID39899500
PMCPMC11790160

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.