Validation of a data-driven motion-compensated PET brain image reconstruction algorithm in clinical patients using four radiotracers.

Ole L Munk, Anders B Rodell, Patricia B Danielsen, Josefine R Madsen, Mie T Sørensen, Niels Okkels, Jacob Horsager, Katrine B Andersen, Per Borghammer, Joel Aanerud and 3 more

Abstract read
In one paragraph

Article in EJNMMI physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Ole L MunkDepartment of Nuclear Medicine & PET centre, Aarhus University Hospital, Aarhus N, 8200, Denmark. olelajmu@rm.dk.ORCID http://orcid.org/0000-0002-7232-5088
Anders B RodellSiemens Healthineers, Runevej 2A, Aarhus V, 8210, Denmark.
Patricia B DanielsenDepartment of Electrical and Computer Engineering, Aarhus University, Aarhus N, 8200, Denmark.
Josefine R MadsenDepartment of Nuclear Medicine & PET centre, Aarhus University Hospital, Aarhus N, 8200, Denmark.
Mie T SørensenDepartment of Electrical and Computer Engineering, Aarhus University, Aarhus N, 8200, Denmark.
Niels OkkelsDepartment of Nuclear Medicine & PET centre, Aarhus University Hospital, Aarhus N, 8200, Denmark.
Jacob HorsagerDepartment of Nuclear Medicine & PET centre, Aarhus University Hospital, Aarhus N, 8200, Denmark.
Katrine B AndersenDepartment of Nuclear Medicine & PET centre, Aarhus University Hospital, Aarhus N, 8200, Denmark.
Per BorghammerDepartment of Nuclear Medicine & PET centre, Aarhus University Hospital, Aarhus N, 8200, Denmark.
Joel AanerudDepartment of Nuclear Medicine & PET centre, Aarhus University Hospital, Aarhus N, 8200, Denmark.
Judson JonesSiemens Medical Solutions USA, Inc., 810 Innovation Drive, Knoxville, TN, 37932, USA.
Inki HongSiemens Medical Solutions USA, Inc., 810 Innovation Drive, Knoxville, TN, 37932, USA.
Sven ZuehlsdorffSiemens Medical Solutions USA, Inc., 810 Innovation Drive, Knoxville, TN, 37932, USA.

Funding

Aase og Ejnar Danielsens Fond 36456Lundbeck Foundation R-359-2020-2533Michael J. Fox Foundation for Parkinson's Research MJFF-022856
6 · The paper itself

Abstract

purposePatients with dementia symptoms often struggle to limit movements during PET examinations, necessitating motion compensation in brain PET imaging to ensure the high image quality needed for diagnostic accuracy. This study validates a data-driven motion-compensated (MoCo) PET brain image reconstruction algorithm that corrects head motion by integrating the detected motion frames and their associated rigid body transformations into the iterative image reconstruction. Validation was conducted using phantom scans, healthy volunteers, and clinical patients using four radiotracers with distinct tracer activity distributions.

methodsWe conducted technical validation experiments of the algorithm using Hoffman brain phantom scans during a series of controlled movements, followed by two blinded reader studies assessing image quality between standard images and MoCo images in 38 clinical patients receiving dementia scans with [

resultsThe Hoffman brain phantom study demonstrated the algorithm's capability to detect and correct for even minimal movements, 1-mm translations and 1⁰ rotations, applied to the phantom. Within the clinical cohort, where standard images were deemed suboptimal or non-diagnostic, all MoCo images were classified as having acceptable diagnostic quality. In the research cohort, MoCo images consistently matched or surpassed the standard image quality even in cases with minimal head movement, and the MoCo algorithm never led to degraded image quality.

conclusionThe PET brain MoCo reconstruction algorithm was robust and worked well for four different tracers with markedly different uptake patterns. Moco images markedly improved the image quality for patients who were unable to lie still during a PET examination and obviated the need for any repeat scans. Thus, the method was clinically feasible and has the potential for improving diagnostic accuracy.

Indexed as

BrainData drivenDementiaMotion correctionPETReconstruction

Identifiers

PMID39899171
PMCPMC11790531

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.