Evidence map›Paper›PMID 39897751›Full record

ArticleRadiology case reports2025

A case of aseptic loosening after total knee replacement with porous-coated mega prosthesis despite progression of extra bone growth.

Ryota Miyamoto, Yasushi Goto, Toshitaka Fujito, Hirohito Abe, Yasuo Kunugiza

Abstract readCase Reports
In one paragraph

Article in Radiology case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ryota MiyamotoDepartment of Orthopaedics, Osaka International Cancer Institute, Osaka, Japan.
Yasushi GotoDepartment of Orthopaedic Surgery, Japan Community Health Care Organization Hoshigaoka Medical Center, Osaka, Japan.
Toshitaka FujitoDepartment of Orthopaedic Surgery, National Hospital Organization Osaka National Hospital, Osaka, Japan.
Hirohito AbeDepartment of Orthopaedic Surgery, Japan Community Health Care Organization Hoshigaoka Medical Center, Osaka, Japan.
Yasuo KunugizaDepartment of Orthopaedic Surgery, Japan Community Health Care Organization Hoshigaoka Medical Center, Osaka, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Total knee replacement with mega prosthesis for periprosthetic fractures after total knee arthroplasty is related to early functional recovery, but aseptic loosening of the implant has been a major reoperation factor in the long-term outcome of total knee replacement with mega prosthesis. Extracortical bone formation caused by bone-collar interface osteointegration may decrease the probability of aseptic loosening by promoting bone formation and improving bone-implant fixation. Here, we report a case of total knee replacement using mega prosthesis with porous-coated collar showing extra bone growth without osteointegration of prosthesis and leading to aseptic loosening.

Indexed as

Aseptic looseningExtracortical bone growthMegaprosthesisRadio lucent line

Identifiers

PMID39897751
PMCPMC11786797