ArticlePractical laboratory medicine2025
Complete blood count in neonatal Intensive care Unit (NICU): Performance comparison between POCT Sight OLO® and Sysmex XN-9100™ hematology analyzers.
Article in Practical laboratory medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Hemoscreen Point-of-Care Analyzer Compared With Sysmex XN-1000 for Complete Blood Count in Pediatric Inpatients Aged 2 Months to 17 Years.International journal of laboratory hematology · 2026Article
- Iron Deficiency Diagnosis in Sub-Saharan Africa: Challenges, Barriers, and Opportunities.Anemia · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and aims: The use of a POCT (Point Of Care Test) could help in reducing the impact of pre-analytical errors in particular in challenging newborn samples.The study purpose is to compare the POCT Sight OLO® hematology analyzer, validated for >3 months patients, with the reference system Sysmex XN-9100™ in Neonatal Intensive Care Unit (NICU). Material and methods: The two analyzers were compared through Passing-Bablok regression analysis and Bland-Altman plot. Results: We analyzed 65 blood samples, in detail 38 from adults and 27 from newborns.The regression analysis results performed in the newborn and adult patients showed a good agreement between the two instruments. The evaluation of the Bland-Altman plots showed comparable values of bias <10 % for the most of parameters.The evaluation of sample flags for the presence of distributional and morphological abnormalities showed a partial accordance between the two approaches, but the POCT exhibited good performance compared to the final report revised by the laboratory specialist. Conclusions: The comparison of the two instruments demonstrated that they provide comparable blood counts, also in patients aged <3 months. The POCT allows having reliable analytical data and faster turning around time, particularly useful in NICU.