Evidence map›Paper›PMID 39896182›Full record

ArticleFrontiers in oncology2024

Needle tracking and segmentation in breast ultrasound imaging based on spatio-temporal memory network.

Qiyun Zhang, Jiawei Chen, Jinhong Wang, Haolin Wang, Yi He, Bin Li, Zhemin Zhuang, Huancheng Zeng

Abstract read
In one paragraph

Article in Frontiers in oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Qiyun Zhang *College of Engineering, Shantou University, Shantou, Guangdong, China.
Jiawei Chen *College of Engineering, Shantou University, Shantou, Guangdong, China.
Jinhong WangDepartment of Ultrasound, Shantou Chaonan Minsheng Hospital, Shantou, Guangdong, China.
Haolin WangCollege of Engineering, Shantou University, Shantou, Guangdong, China.
Yi HeShantou University Medical College, Shantou, Guangdong, China.
Bin LiProduct Development Department, Shantou Institute of Ultrasonic Instruments, Shantou, Guangdong, China.
Zhemin ZhuangCollege of Engineering, Shantou University, Shantou, Guangdong, China.
Huancheng ZengThe Breast Center, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Ultrasound-guided needle biopsy is a commonly employed technique in modern medicine for obtaining tissue samples, such as those from breast tumors, for pathological analysis. However, it is limited by the low signal-to-noise ratio and the complex background of breast ultrasound imaging. In order to assist physicians in accurately performing needle biopsies on pathological tissues, minimize complications, and avoid damage to surrounding tissues, computer-aided needle segmentation and tracking has garnered increasing attention, with notable progress made in recent years. Nevertheless, challenges remain, including poor ultrasound image quality, high computational resource requirements, and various needle shape. Methods: This study introduces a novel Spatio-Temporal Memory Network designed for ultrasound-guided breast tumor biopsy. The proposed network integrates a hybrid encoder that employs CNN-Transformer architectures, along with an optical flow estimation method. From the Ultrasound Imaging Department at the First Affiliated Hospital of Shantou University, we developed a real-time segmentation dataset specifically designed for ultrasound-guided needle puncture procedures in breast tumors, which includes ultrasound biopsy video data collected from 11 patients. Results: Experimental results demonstrate that this model significantly outperforms existing methods in improving the positioning accuracy of needle and enhancing the tracking stability. Specifically, the performance metrics of the proposed model is as follows: IoU is 0.731, Dice is 0.817, Precision is 0.863, Recall is 0.803, and F1 score is 0.832. By advancing the precision of needle localization, this model contributes to enhanced reliability in ultrasound-guided breast tumor biopsy, ultimately supporting safer and more effective clinical outcomes. Discussion: The model proposed in this paper demonstrates robust performance in the computer-aided tracking and segmentation of biopsy needles in ultrasound imaging, specifically for ultrasound-guided breast tumor biopsy, offering dependable technical support for clinical procedures.

Indexed as

breast cancercomputer-aided diagnosisneedle segmentationpunch biopsyultrasound