Evidence map›Paper›PMID 39896012›Full record

ArticlePeerJ. Computer science2025

UltraTimTrack: a Kalman-filter-based algorithm to track muscle fascicles in ultrasound image sequences.

Tim J van der Zee, Paolo Tecchio, Daniel Hahn, Brent J Raiteri

Abstract read
In one paragraph

Article in PeerJ. Computer science, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Tim J van der ZeeBiomedical Engineering Graduate Program, University of Calgary, Calgary, Canada.
Paolo TecchioDepartment of Human Movement Science, Ruhr University Bochum, Bochum, Germany.
Daniel HahnDepartment of Human Movement Science, Ruhr University Bochum, Bochum, Germany.
Brent J RaiteriDepartment of Human Movement Science, Ruhr University Bochum, Bochum, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Brightness-mode (B-mode) ultrasound is a valuable tool to non-invasively image skeletal muscle architectural changes during movement, but automatically tracking muscle fascicles remains a major challenge. Existing fascicle tracking algorithms either require time-consuming drift corrections or yield noisy estimates that require post-processing. We therefore aimed to develop an algorithm that tracks fascicles without drift and with low noise across a range of experimental conditions and image acquisition settings. Methods: We applied a Kalman filter to combine fascicle length and fascicle angle estimates from existing and openly-available UltraTrack and TimTrack algorithms into a hybrid algorithm called UltraTimTrack. We applied the hybrid algorithm to ultrasound image sequences collected from the human medial gastrocnemius of healthy individuals ( Results: The proposed algorithm yielded low-noise estimates like UltraTrack and was drift-free like TimTrack across the broad range of conditions we tested. Over 120 cyclical contractions, fascicle length and fascicle angle deviations of UltraTimTrack accumulated to 2.1 ± 1.3 mm (mean ± sd) and 0.8 ± 0.7 deg, respectively. This was considerably less than UltraTrack (67.0 ± 59.3 mm, 9.3 ± 8.6 deg) and similar to TimTrack (1.9 ± 2.2 mm, 0.9 ± 1.0 deg). Average cycle-to-cycle variability of UltraTimTrack was 1.4 ± 0.4 mm and 0.6 ± 0.3 deg, which was similar to UltraTrack (1.1 ± 0.3 mm, 0.5 ± 0.1 deg) and less than TimTrack (3.5 ± 1.0 mm, 1.4 ± 0.5 deg). UltraTimTrack was less affected by experimental conditions and image acquisition settings than its parent algorithms. It also yielded similar or lower root-mean-square deviations from manual tracking for previously published image sequences (fascicle length: 2.3-2.6 mm, fascicle angle: 0.8-0.9 deg) compared with a recently-proposed hybrid algorithm (4.7 mm, 0.9 deg), and the recently-proposed DL_Track algorithm (3.8 mm, 3.9 deg). Furthermore, UltraTimTrack's processing time (0.2 s per image) was at least five times shorter than that of these recently-proposed algorithms. Conclusion: We developed a Kalman-filter-based algorithm to improve fascicle tracking from B-mode ultrasound image sequences. The proposed algorithm provides low-noise, drift-free estimates of muscle architectural changes that may better inform muscle function interpretations.

Indexed as

Ankle dynamometryB-mode ultrasonographyFascicle lengthHough transformMedial gastrocnemiusMuscle architectureMuscle contractionOptical flowPennation angleUltrasound imaging

Identifiers

PMID39896012
PMCPMC11784871

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.