Evidence map›Paper›PMID 39893296›Full record

Observational studyJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2025

Safety and efficacy of a temperature-controlled ablation system for ventricular tachycardia: Results from the TRAC-VT study.

Josef Kautzner, Javier Moreno, Claudio Tondo, Frédéric Anselme, James Burrell, Daniel Becker, Petr Peichl, Ian Patchett, Tarvinder Dhanjal

Abstract readMulticenter StudyObservational Study
In one paragraph

Observational study in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Detailed analysis of electrogram peak frequency to guide ventricular tachycardia substrate mapping.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Josef KautznerInstitute for Clinical and Experimental Medicine, Prague, Czechia. josef.kautzner@ikem.cz.
Javier MorenoDepartment of Cardiology, Hospital Universitario Ramón y Cajal, Madrid, Spain.
Claudio TondoDept of Clinic. Electrophysiology & Cardiac Pacing, Heart Rhythm Center, Centro Cardiologico Monzino, Milan, Italy.
Frédéric AnselmeCardiologie, CHU de Rouen, Rouen, France.
James Burrell, Medtronic, Minneapolis, USA.
Daniel Becker, Medtronic, Minneapolis, USA.ORCID http://orcid.org/0000-0001-8023-9246
Petr PeichlInstitute for Clinical and Experimental Medicine, Prague, Czechia.
Ian PatchettDepartment of Cardiology, University Hospitals Coventry & Warwickshire NHS Trust, Coventry, UK.
Tarvinder DhanjalDepartment of Cardiology, University Hospitals Coventry & Warwickshire NHS Trust, Coventry, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCatheter ablation using radiofrequency (RF) energy is an established treatment for ventricular tachycardia (VT). Tissue temperature is a key determinant of successful lesion creation, and yet, it is difficult to measure during conventional RF ablation because of the cooling effect of high-flow rate saline irrigation. The TRAC-VT study evaluated the safety and efficacy of a novel irrigated RF ablation system modulating power based on real-time tissue temperature.

methodsPatients with sustained monomorphic VT and structural heart disease (SHD) were enrolled. Catheter ablation was performed in temperature-control mode (irrigation 8 ml/min, temperature set-points 55 or 60 °C, and power output ≤ 50 W), with RF applications for ≤ 45 s. The primary safety endpoint was a composite of cardiovascular-specific serious procedure-related adverse events within 30 days post-ablation. The primary effectiveness endpoint was acute success (i.e., non-inducibility of all clinically relevant VTs).

resultsThirty-eight patients were enrolled with monomorphic VT (age 68 ± 12 years and 84% male), with an average of 1.7 ± 1.2 VTs targeted per patient. In total, 41 ± 23 RF applications per patient were delivered. Acute procedural success was 100% (95% CI, 91-100%). No primary safety endpoints were observed. Six-month follow-up was completed in 92% of patients with 81% (95% CI, 65-91%) freedom from sustained or treated VT. A repeat ablation was performed in three patients.

conclusionsAblation of VT in SHD, using a temperature-controlled irrigated RF catheter, was safe and effective with a low rate of VT recurrence at 6 months.

Indexed as

Catheter AblationTachycardia, VentricularAgedEquipment DesignFemaleHumansMaleMiddle AgedTherapeutic IrrigationTreatment OutcomeCardiac arrhythmiaDiamondTempRadiofrequency catheter ablationTemperature controlledVentricular tachycardia

Identifiers

PMID39893296
PMCPMC12399702

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.