Evidence map›Paper›PMID 39888888›Full record

ArticlePloS one2025

Accelerated dynamic magnetic resonance imaging from Spatial-Subspace Reconstructions (SPARS).

Alexander J Mertens, Hai-Ling Margaret Cheng

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Alexander J MertensThe Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, Toronto, Canada.ORCID 0000-0001-5172-0444
Hai-Ling Margaret ChengThe Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, Toronto, Canada.ORCID 0000-0002-0733-9512

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) ideally requires a high spatial and a high temporal resolution, but hardware limitations prevent acquisitions from achieving both simultaneously-either high temporal resolution is exchanged for spatial resolution, or vice versa. Even state-of-the-art image reconstruction techniques that infer missing data in a sparse acquisition space cannot recover the loss of spatial detail, especially at high temporal acceleration rates. The purpose of this paper is to introduce the concept of spatial subspace reconstructions (SPARS) and demonstrate its ability to reconstruct high spatial resolution dynamic images from as few as one acquired k-space spoke per time frame in a dynamic series. Briefly, a low-temporal-high-spatial resolution organization of the acquired raw data is used to estimate the basis vectors of the spatial subspace in which the high-temporal-high-spatial ground truth data resides. This subspace is then used to estimate entire images from single k-space spokes. In both simulated and human in-vivo data, the proposed SPARS reconstruction method outperformed standard GRASP and GRASP-Pro reconstruction, providing a shorter reconstruction time and yielding higher accuracy from both a spatial and temporal perspective.

Indexed as

Image Processing, Computer-AssistedMagnetic Resonance ImagingAlgorithmsHumans

Identifiers

PMID39888888
PMCPMC11785264

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.