Clinical Evaluation of the NaviNetics Stereotactic System Using Intraoperative Portable Surgical Imaging System in DBS Surgery.

Jee Won Shin, Kristen M Scheitler, Basel Sharaf, Ian Mandybur, Sara Hussein, Bryan T Klassen, Nick Gregg, Sanjeet S Grewal, Kai J Miller, Hojin Shin and 4 more

Abstract read
In one paragraph

Article in Operative neurosurgery (Hagerstown, Md.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Jee Won ShinMedical Scientist Training Program, Mayo Clinic, Rochester , Minnesota , USA.ORCID 0000-0001-8283-484
Kristen M ScheitlerDepartment of Neurologic Surgery, Mayo Clinic, Rochester , Minnesota , USA.
Basel SharafDepartment of Plastic and Reconstructive Surgery, Mayo Clinic, Rochester , Minnesota , USA.
Ian MandyburDepartment of Neurologic Surgery, Mayo Clinic, Rochester , Minnesota , USA.
Sara HusseinDepartment of Neurologic Surgery, Mayo Clinic, Rochester , Minnesota , USA.
Bryan T KlassenDepartment of Neurology, Mayo Clinic, Rochester , Minnesota , USA.
Nick GreggDepartment of Neurology, Mayo Clinic, Rochester , Minnesota , USA.
Sanjeet S GrewalDepartment of Neurologic Surgery, Mayo Clinic, Jacksonville , Florida , USA.
Kai J MillerDepartment of Neurologic Surgery, Mayo Clinic, Rochester , Minnesota , USA.
Hojin ShinDepartment of Neurologic Surgery, Mayo Clinic, Rochester , Minnesota , USA.
Jin-Woo ChangDeparment of Neurosurgery, Korea University, Seoul , South Korea.
Yoonbae OhDepartment of Neurologic Surgery, Mayo Clinic, Rochester , Minnesota , USA.
David VansickleNeurosurgery One, AdventHealth Littleton , Colorado , USA.
Kendall H LeeDepartment of Neurologic Surgery, Mayo Clinic, Rochester , Minnesota , USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectivesA typical workflow for deep brain stimulation (DBS) surgery consists of head frame placement, followed by stereotactic computed tomography (CT) or MRI before surgical implantation of the hardware. At some institutions, this workflow is prolonged when the imaging scanner is located far away from the operating room, thereby increasing workflow times by the addition of transport times. Recently, the intraoperative O-arm has been shown to provide accurate image fusion with preoperative CT or MR imaging, suggesting the possibility of obtaining an intraoperative localization scan and postoperative confirmation. In this article, we aim to evaluate the compatibility of the stereotactic frame system with the intraoperative O-arm system regarding lead accuracy and surgical flow.

methodsA total of 17 patients undergoing DBS surgery for movement disorders were evaluated. One patient underwent both the stereotactic CT and O-arm localization, while 16 patients underwent only intraoperative O-arm localization. Following lead placement, intraoperative O-arm imaging was obtained to evaluate the accuracy of the lead placement. Accuracy was defined as the error measured as the distance from the center of the planned trajectory to the cannula.

resultsLess than 0.1 mm difference was found between the O-arm imaging technique and CT image localization of the NaviNetics stereotactic head frame in DBS surgery. Of the 16 patients who underwent the intraoperative O-arm imaging alone, the targets included bilateral ventral intermediate nucleus (16 leads), bilateral globus pallidus internus (4 leads), and subthalamic nucleus (12 leads). The mean ± SD radial error in the probe's eye view was 0.71 ± 0.33 mm for n = 32 leads. No tract hemorrhage was observed.

conclusionIntraoperative O-arm imaging can be used safely and effectively for stereotactic registration and lead placement confirmation with the stereotactic system in both awake and asleep DBS surgery.

Indexed as

Deep Brain StimulationMovement DisordersStereotaxic TechniquesAdultAgedFemaleHumansMagnetic Resonance ImagingMaleMiddle AgedParkinson DiseaseSubthalamic NucleusTomography, X-Ray ComputedDeep brain stimulationO-arm imagingStereotactic head frame

Identifiers

PMID39883866
PMCPMC12273644

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.