Trial reportFuture cardiology2025
Comparison of in-clinic assessment of 6MWT by conventional method and using wearable sensors for patients with ATTR-CM.
Trial report in Future cardiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03860935 (A Phase 3, Randomized, Double-Blind, Placebo-Controlled Study of the Efficacy and Safety of AG10 in Subjects With Symptomatic Transthyretin Amyloid Cardiomyopathy), which is not on this map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Phase 3, Randomized, Double-Blind, Placebo-Controlled Study of the Efficacy and Safety of AG10 in Subjects With Symptomatic Transthyretin Amyloid Cardiomyopathy (ATTRibute-CM Trial)
Who cites it
1 citing paper in PubMed.
- Wearables for Telemonitoring in ATTR-Amyloidosis: Current Perspectives.Sensors (Basel, Switzerland) · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe 6-minute walk test (6MWT) is used to assess submaximal exercise capacity in clinical trials. Conducting the 6MWT can be challenging when patients cannot visit the clinic due to physical/travel limitations. This pilot study assessed the feasibility of conducting the 6MWT using wearable sensors for patients with transthyretin amyloid cardiomyopathy.
methodsParticipants were enrolled in the phase 3 ATTRibute-CM trial. Sensors were positioned on patients' feet and lower back during the 6MWT. The 6-minute walk distance (6MWD) was compared with the distance measured by a trained observer during a concurrent conventional test. Pearson and concordance correlation coefficients were estimated.
resultsTwelve participants from five centers participated; 11 had evaluable data. Mean 6MWD was 330.3 m (conventional method) and 335.1 m (wearable sensors); mean difference (SD) was 4.7 m (10.95). Pearson and concordance correlation coefficients for 6MWD were 0.998 (95% CI: 0.992-0.999) and 0.997 (95% CI: 0.991-0.999), respectively.
conclusionsThe 6MWD measured using wearable sensors and by the conventional method were closely correlated. Conducting the 6MWT with wearable sensors may be feasible and as reliable as the conventional method in a monitored clinic setting. Whether at-home 6MWD measured by wearable sensors correlates with in-clinic monitoring deserves further study. CLINICAL
trial registrationClinicalTrials.gov identifier is NCT03860935.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.