Evidence map›Paper›PMID 39877617›Full record

ArticleHeliyon2025

Introducing an integrated approach for fire safety assessment in healthcare facilities by interval valued neutrosophic-AHP and Fuzzy Inference System.

Samaneh Salari, Ali Karimi

Abstract read
In one paragraph

Article in Heliyon, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Samaneh SalariDepartment of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.
Ali KarimiDepartment of Occupational Health Engineering, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fire safety in healthcare facilities is extremely important due to limited evacuation capacity of occupants. Therefore, poor fire safety precautions lead to more fatalities and financial losses. This study introduces an effective fire risk management approach for healthcare buildings utilizing an interval valued neutrosophic-fuzzy framework. This framework identifies fire risks and determine appropriate safety measures. In addition, essential fire risk criteria in healthcare centers were systematically identified through a multi-factor decision-making process, employing the Fuzzy-Delphi technique and a comprehensive literature review. The proposed framework initially determines the importance weights of these factors using the Interval Valued Neutrosophic-Analytical Hierarchy Process (IVN-AHP). Subsequently, three main parameters - Potential Risk Level (PRL), Acceptance Risk Level (ARL) and Protection Level (PL) - were calculated as alternatives in IVN-AHP technique using novel mathematical equations. A fuzzy inference system (FIS) was then employed to estimate the risk magnitude and subsequently classify departments within the healthcare building based on their risk level. The fire risk control strategy is then determined based on this risk classification. The proposed approach was applied to departments within a hospital in Iran. Its validity was evaluated by comparing the results with the comprehensive Fire Risk Assessment Method for Engineering (FRAME) technique. Additionally, the sensitivity of the IVN-AHP in determining the weights of factors and alternatives was validated using real data. The results revealed that the utilities and kitchen departments exhibited a critical risk class exceeding 50 %. Furthermore, the operating room, laundry, post-NICU 1 and 2, and waste disposal were classified as critical, with more than 50 % falling within the major risk class. A strong correlation coefficient of 99.1 % was observed between the Fire Risk Magnitude (FRM) obtained using the proposed farmwork and the FRM for occupants obtained using the FRAME technique. These findings demonstrate the applicability and reliability of the proposed approach as a valuable tool for risk management and decision-making in healthcare facilities.

Indexed as

AHPDelphi techniqueFire riskFire risk assessmentFISHealthcareHospitalMulti-criteria decision-making

Identifiers

PMID39877617
PMCPMC11773059

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.