Evidence map›Paper›PMID 39866888›Full record

ArticleDigital health

Continuous atrial fibrillation monitoring using a wearable smartwatch: Using long-term Holter as reference.

Yannan Pan, Erdong Chen, Shihui Jie, Dongbo Huo, Zhongru Ding, Jing Zhou, Jie Jiang, Jianping Li, Yong Huo

Abstract read
In one paragraph

Article in Digital health. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Observational
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yannan PanDepartment of Cardiology, Peking University First Hospital, Beijing, China.ORCID https://orcid.org/0000-0003-4868-6649
Erdong ChenDepartment of Cardiology, Peking University First Hospital, Beijing, China.ORCID https://orcid.org/0000-0002-3401-1512
Shihui JieDepartment of Cardiology, Peking University First Hospital, Beijing, China.
Dongbo HuoDepartment of Cardiology, Peking University First Hospital, Beijing, China.
Zhongru DingHuami (Beijing) Information Technology Co. Ltd, Beijing, China.
Jing ZhouDepartment of Cardiology, Peking University First Hospital, Beijing, China.
Jie JiangDepartment of Cardiology, Peking University First Hospital, Beijing, China.ORCID https://orcid.org/0000-0002-4077-0056
Jianping LiDepartment of Cardiology, Peking University First Hospital, Beijing, China.
Yong HuoDepartment of Cardiology, Peking University First Hospital, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Wearables satisfactorily detect atrial fibrillation (AF) longer than 1 hour. Our study aims to evaluate smartwatch performances for long-term AF monitoring, including AF with short durations. Methods: This prospective study enrolled AF patients from 2020 to 2023. Diagnostic efficacy of the Amazfit smartwatch, with AF-identifying algorithms from photoplethysmography (PPG) and single-lead electrocardiogram (ECG), was compared with a 7-day Holter. Primary analysis included smartwatch diagnostics to identify AF longer than 5 minutes. Secondary analyses evaluated smartwatch performances under different settings and compared AF burdens between the smartwatch and Holter. Results: The study analyzed 72 patients (48 males, mean age 65.4 ± 8.5) with 914 AF episodes lasting 834.7 hours, including 142 longer-than-5-minute AF episodes. Smartwatch recording time was 8927.6 hours. By individual, sensitivities and specificities of AF longer than 5 minutes were 100.0% and 83.7% for PPG and 89.7% and 67.4% for the ECG algorithm. Positive and negative predictive values were 94.9% and 99.9% for PPG and 77.6% and 99.8% for ECG. Optimal AF durations to be identified by PPG and ECG algorithms were 1.358 and 16.708 minutes. Smartwatch performances varied across AF durations and between day-time and night-time. Strong correlations (PPG: Conclusions: Compared with long-term Holter, the wearable smartwatch had satisfying qualitative and quantitative diagnostic performances for continuous AF monitoring. Susceptibility to false positives led to modest specificity. Smartwatch performances were affected by AF durations and time periods. Registration: ChiCTR2000040035.

Indexed as

artificial intelligencecardiologyCardiovascular diseasedigital healthwearables

Identifiers

PMID39866888
PMCPMC11758528

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.