Evidence map›Paper›PMID 39866728›Full record

ArticleF1000Research2024

Effect of non-contact induction heating on HA coatings and bone cement, an ex vivo study.

Robert Kamphof, Dr Giuseppe Cama, Jeroen Mesman-Vergeer, Dr Rob G H H Nelissen, Dr Bart G C W Pijls

Abstract read
In one paragraph

Article in F1000Research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Robert KamphofDepartment of Orthopaedics, Leiden University Medical Center, Leiden, Albinusdreef 2, 2333 ZA, The Netherlands.ORCID https://orcid.org/0000-0002-4154-4739
Dr Giuseppe CamaCAM Bioceramics B.V., Leiden, Zernikedreef 6, 2333 CL, The Netherlands.
Jeroen Mesman-VergeerFMD / Institute LION / Leiden University, Leiden, Niels Bohrweg 2, 2333 CA, The Netherlands.
Dr Rob G H H NelissenDepartment of Orthopaedics, Leiden University Medical Center, Leiden, Albinusdreef 2, 2333 ZA, The Netherlands.
Dr Bart G C W PijlsDepartment of Orthopaedics, Leiden University Medical Center, Leiden, Albinusdreef 2, 2333 ZA, The Netherlands.ORCID https://orcid.org/0000-0001-5351-5057

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Prosthetic joint infection is a serious complication that can arise after total joint replacement surgery. When bacteria colonise an orthopaedic implant, they form biofilms that protect them from their environment, making them difficult to remove. Treatment is further complicated by a global rise of antimicrobial resistance. These protective mechanisms make treatment of prosthetic joint infection increasingly complex. Non-contact induction heating is an upcoming technology that uses heat to eradicate bacteria that are present on the surface of metallic implants. This study aims to provide insight into the feasibility of using non-contact induction heating on metallic implants that are in direct contact with other biomaterials, such as coatings composed of hydroxyapatite and bone cement composed of poly (methyl methacrylate) (PMMA). Methods: Characterisation of hydroxyapatite coatings and adhesion strength tests were conducted according to standards set by the International Organisation for Standardisation (ISO 13779-2). The fixation strength of acrylic bone cement was tested according to an adapted method from ISO. Results: It was found that non-contact induction heating did not significantly affect the adhesion strength of hydroxyapatite coatings. In contrast to hydroxyapatite coatings, acrylic bone cement softened temporarily as the temperature exceeded the glass transition temperature (83.38 ± 10.88°C). However, the induction heating temperature had no significant effect on the fixation strength after the cement was allowed to cool down. Conclusion: This study shows the feasibility of using non-contact induction heating up to 80°C when bone cement or ceramic coatings are present in contact with infected metallic implants.

Indexed as

Bone CementsCoated Materials, BiocompatibleDurapatiteHot TemperatureMaterials TestingPolymethyl MethacrylateProstheses and ImplantsBone CementsCoated Materials, BiocompatibleDurapatitePolymethyl Methacrylateacrylic bone cementAMRcalcium phosphatehydroxyapatiteimplant coatingnon-contact induction heatingPJIPMMAtitanium implants

Identifiers

PMID39866728
PMCPMC11757918

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.