Evaluation of charge summing correction in CdTe-based photon-counting detectors for breast CT: performance metrics and image quality.
Article in Journal of medical imaging (Bellingham, Wash.), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Comparative Evaluation of Machine Learning and Conventional Material Decomposition Algorithms for Spectral Chest Radiography Using a CdTe Photon-Counting Detector.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT). Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.1 mm, operated in both standard mode [single pixel (SP)] and charge summing correction mode [anticoincidence (AC)]. A tungsten anode source operated at 55 kVp with 2-mm aluminum external filtration and tube currents of 25, 100, and 200 mA with corresponding exposure times of 20, 5, and 2.5 ms were employed to study the effects of X-ray fluence and pulse pileup. Performance comparisons between AC and SP modes are performed in both projection and image reconstructed spaces. In the projection space, performance metrics include count rate, energy resolution, uniformity, modulation transfer function (MTF), and noise power spectrum (NPS). In the image space, performance metrics consist of contrast-to-noise ratio (CNR), uniformity, NPS, and iodine quantification accuracy. For both acquisition modes, signal-to-thickness calibration, for gain and beam hardening corrections, is used before image reconstruction. Images are reconstructed via TIGRE CT software using the standard Feldkamp, Davis, and Kress (FDK) filtered back projection algorithm with a Hann filter and reconstructed with a voxel size of 0.081 mm. Material decomposition is performed using a standard image-based method. Results: In the detector space, the application of hardware-based charge summing correction enhances spectral resolution and improves the spatial resolution of MTF at lower energy thresholds but introduces anomalous edge enhancement effects and artifacts in the MTF at high fluence. A negative noise correlation was observed in AC mode-acquired images. As expected, the AC acquisition mode results in a decreased detector count rate. In the image space, NPS results displayed elevated noise in low-energy AC images. However, at high energy, noise was comparable between both modes. Greater uniformity was observed in SP mode-acquired images. The largest disparity was observed in the iodine quantification test, where the AC mode demonstrates a much stronger linear relationship between estimated and true iodine concentrations than the SP mode. Conclusion: The results are specific to the studied system, reconstruction parameters, and irradiation conditions limited to 200 mA and 0.5 mAs. The AC mode generally provides better energy and MTF resolution at low energy thresholds but with increased noise and reduced uniformity. In image space, charge summing correction improved iodine quantification and CNR at high energy thresholds.