ArticleJournal of orthopaedic surgery and research2025
Mid- to long-term clinical outcomes of modified technique skip-level titanium plate fixation in cervical laminoplasty compared to continuous fixation.
Article in Journal of orthopaedic surgery and research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Clinical efficacy and safety analysis of the "Pre-set screw path technique" in cervical posterior single door laminoplasty with supportive titanium plate fixation: a prospective randomized controlled study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Trial
- CT-based morphometry and Mimics-guided virtual implantation of a facet-fusion-integrated posterior cervical semi-open-door system: an anatomical feasibility study.BMC musculoskeletal disorders · 2025Article
- All-Level Versus Alternative-Level in Unilateral Laminoplasty: A Retrospective Comparative Study.Orthopaedic surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
purposeTo compare the efficacy and safety of skip titanium plates combined with adjacent spinous process suture suspension versus continuous titanium plate fixation in cervical laminoplasty.
methodsA retrospective analysis of 125 patients (62 men, 63 women, average age 60.9 ± 10.4 years) with multilevel cervical spondylotic myelopathy who had cervical laminoplasty with Arch titanium plate fixation from January 2012 to March 2024 in our hospital was done. Patients were stratified into two cohorts based on the fixation technique: Group A (n = 64): Modified technique of skip-level titanium plate fixation (Arch titanium plates at C4 and C6 levels combined with adjacent spinous process suture suspension)Group B (n = 61): Continuous plating (Arch titanium plates applied sequentially from C3 to C7).The comparative analysis focused on perioperative parameters (operative duration, intraoperative blood loss, length of hospital stay), economic factors (hospital costs), and various clinical indicators.
resultsThe average follow up period was (73.0 ± 38.4) months. Both groups showed no significant differences in gender, age, and disease duration (P > 0.05). Group A had lower hospitalization costs, intraoperative blood loss, operation time, and postoperative hospital stay compared to Group B (P < 0.05). Postoperatively, both groups had significant improvements in JOA scores and NDI (P < 0.005), but there were no significant differences in postoperative scores and improvement rates between the two groups (P > 0.05). At 3 months postoperatively and at the last follow-up, the C2-7 Cobb angle and cervical curvature index decreased compared to preoperative values (P < 0.05), with a significant difference in the C2-7 Cobb angle at the last follow-up (P < 0.05). The sagittal diameter of the spinal canal from C3 to C7 significantly increased (P < 0.05), but there were no significant differences in the improvement of C3, C5, and C7 between the two groups (P > 0.05). At 3 months postoperatively, the opening angles of the C4 and C6 laminae in Group A were smaller than those in Group B (P < 0.05), but there were no significant differences at the last follow-up (P > 0.05). The healing of the C4 and C6 laminae in Group B was superior to that in Group A (P < 0.05), but there were no differences in healing at the last follow-up (P > 0.05). The incidence of axial symptoms was similar (10.9% in Group A and 14.8% in Group B, P = 0.523).
conclusionsDuring C3-7 laminoplasty, the clinical efficacy of the method combining mini titanium plate fixation (at C4 and C6) with suture fixation is comparable to that of continuous fixation. Moreover, it has an advantage in cost control.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.