Evidence map›Paper›PMID 39864022›Full record

ArticleEJNMMI physics2025

Count-rate management in

Staffan Jacobsson Svärd, Cecilia Hindorf, Joachim N Nilsson

Abstract read
In one paragraph

Article in EJNMMI physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Staffan Jacobsson SvärdDepartment of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden.ORCID http://orcid.org/0000-0003-3411-7058
Cecilia HindorfDepartment of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden.ORCID http://orcid.org/0000-0002-1855-6723
Joachim N NilssonDepartment of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden. joachim.nilsson@ki.se.ORCID http://orcid.org/0000-0001-7496-9189

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSystem calibration is essential for accurate SPECT/CT dosimetry. However, count losses due to dead time and pulse pileup may cause calibration errors, in particular for

resultsThe sensitivities of two General Electric (GE) Discovery 670 Pro systems were assessed using two Jaszczak phantom geometries. SPECT/CT data were collected over two months, starting with an initial

conclusionsThe results show that adequate corrections for dead-time and pulse-pileup counting losses are essential for accurate calibration. It is argued that loss corrections should be based on total spectrum count rates in projections and not only on the 364.5 keV energy window data. The measurement campaigns presented in this paper, using basic tools and equipment, may serve as a model for establishing routines for count-loss corrections as well as for system calibration and regular control of system sensitivity. The data suggest that analysis of source and count concentration in a homogeneous Jaszczak phantom offers robust calibration, whereas analysis of source strength and counts in a delineated phantom insert offers a practical and robust method for regular quality control.

Indexed as

131ICalibrationDosimetryQuantificationSPECT/CT