Evidence map›Paper›PMID 39860915›Full record

ArticleSensors (Basel, Switzerland)2025

The Application of Supervised Machine Learning Algorithms for Image Alignment in Multi-Channel Imaging Systems.

Kyrylo Romanenko, Yevgen Oberemok, Ivan Syniavskyi, Natalia Bezugla, Pawel Komada, Mykhailo Bezuglyi

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kyrylo RomanenkoDepartment of Computer-Integrated Technologies of Device Production, Faculty of Instrumentation Engineering, National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute", Beresteiskyi Ave., 37, 03056 Kyiv, Ukraine.
Yevgen OberemokDepartment of Quantum Radiophysics and Nanoelectronics, Taras Shevchenko National University of Kyiv, 60 Volodymyrska St., 01033 Kyiv, Ukraine.ORCID 0000-0001-6439-721X
Ivan SyniavskyiDepartment of Computer-Integrated Technologies of Device Production, Faculty of Instrumentation Engineering, National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute", Beresteiskyi Ave., 37, 03056 Kyiv, Ukraine.ORCID 0000-0002-5285-2358
Natalia BezuglaDepartment of Computer-Integrated Technologies of Device Production, Faculty of Instrumentation Engineering, National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute", Beresteiskyi Ave., 37, 03056 Kyiv, Ukraine.
Pawel KomadaDepartment of Electronics and Information Techniques, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, 38D Nadbystrzycka Street, 20-618 Lublin, Poland.ORCID 0000-0002-9032-9285
Mykhailo BezuglyiDepartment of Computer-Integrated Technologies of Device Production, Faculty of Instrumentation Engineering, National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute", Beresteiskyi Ave., 37, 03056 Kyiv, Ukraine.ORCID 0000-0003-0624-0585

Funding

Lublin University of Technology FD-20/EE-2/312
6 · The paper itself

Abstract

This study presents a method for aligning the geometric parameters of images in multi-channel imaging systems based on the application of pre-processing methods, machine learning algorithms, and a calibration setup using an array of orderly markers at the nodes of an imaginary grid. According to the proposed method, one channel of the system is used as a reference. The images from the calibration setup in each channel determine the coordinates of the markers, and the displacements of the marker centers in the system's channels relative to the coordinates of the centers in the reference channel are then determined. Correction models are obtained as multiple polynomial regression models based on these displacements. These correction models align the geometric parameters of the images in the system channels before they are used in the calculations. The models are derived once, allowing for geometric calibration of the imaging system. The developed method is applied to align the images in the channels of a module of a multispectral imaging polarimeter. As a result, the standard image alignment error in the polarimeter channels is reduced from 4.8 to 0.5 pixels.

Indexed as

geometric calibrationimage alignmentimage analysisimage processingmachine learning algorithmsmulti-channel imaging systems

Identifiers

PMID39860915
PMCPMC11768783

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.