ArticleSensors (Basel, Switzerland)2025
A Magnetoelectric Distance Estimation System for Relative Human Motion Tracking.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Pilot Study: Step Width Estimation with Body-Worn Magnetoelectric Sensors.Sensors (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
Clinical motion analysis plays an important role in the diagnosis and treatment of mobility-limiting diseases. Within this assessment, relative (point-to-point) tracking of extremities could benefit from increased accuracy. Given the limitations of current wearable sensor technology, supplementary spatial data such as distance estimates could provide added value. Therefore, we propose a distributed magnetic tracking system based on early-stage demonstrators of novel magnetoelectric (ME) sensors. The system consists of two body-worn magnetic actuators and four ME sensor arrays (body-worn and fixed). It is enabled by a comprehensive signal processing framework with sensor-specific signal enhancement and a gradient descent-based system calibration. As a pilot study, we evaluated the technical feasibility of the described system for motion tracking in general (Scenario A) and for operation during treadmill walking (Scenario B). At distances of up to 60 cm, we achieved a mean absolute distance error of 0.4 cm during gait experiments. Our results show that the modular system is capable of centimeter-level motion tracking of the lower extremities during treadmill walking and should therefore be investigated for clinical gait parameter assessment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.