Modeling of Measuring Transducers for Relay Protection Systems of Electrical Installations.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
The process of establishing relay protection and automation (RPA) settings for electric power systems (EPSs) entails complex calculations of operating modes. Traditionally, these calculations are based on symmetrical components, which require the building of equivalent circuits of various sequences. This approach can lead to errors both when identifying the operating modes and when modeling the RPA devices. Proper modeling of measuring transformers (MTs), symmetrical component filters (SCFs), and circuits connected to them effectively solves this problem, enabling the configuration of relay protection and automation systems. The methods of modeling the EPS in phase coordinates are proposed to simultaneously determine the operating modes of high-voltage networks and secondary circuits connected to the current and voltage transformers. The MT and SCF models are developed to concurrently identify the operating modes of secondary wiring circuits and calculate the power flow in the controlled EPS segments. This method is effective in addressing practical problems related to the configuration of the relay protection and automation systems. It can also be used when establishing cyber-physical power systems. For a comprehensive check of the adequacy of the MT models, 140 modes of the electric power system were determined which corresponded to time-varying traction loads. Based on the results of calculating the complexes of currents and voltages at the MT terminals, parametric identification of the power transmission line was performed. Based on this, the model of this transmission line was adjusted; repeated modeling was carried out, and errors were calculated. The modeling results showed a high accuracy when calculating the modules and phases of voltages using the identified model. The average error value for current modules was 0.6%, and for angles, it was 0.26°.