ArticleMaterials (Basel, Switzerland)2025
The Effect of Relative Humidity on Creep Behavior of Cement Paste Microprism.
Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Advances in Ultra-High Performance Concretes and Cementitious Composites.Materials (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Despite decades of extensive studies, the mechanism of concrete creep remains a subject of debate, mainly due to the complex nature of cement microstructure. This complexity is further amplified by the interplay between water and the cement microstructure. The present study aimed to better understand the creep mechanism through creep tests on microprisms of cement paste at hygral equilibrium. First, microprisms with dimensions of 150 mm × 150 mm × 300 mm were prepared by precision cutting from a cement paste specimen with a water-to-cement ratio of 0.4. Subsequently, uniaxial compression and creep tests were carried out on these microprisms in a chamber with controlled relative humidity (RH). To mitigate the impact of plasticity and damage, the applied peak load was set to generate a stress level that was approximately 40% of the compressive strength. Moreover, an analytical coefficient φ was formulated to account for the foundation effect on microprism creep, agreeing with the numerical analysis employing the finite element method. Our findings showed that the microscale creep compliance varied when the RH level was changed from 90% to 11%. Furthermore, logarithmic and power-law models were both applied to simulate creep curves. Lastly, the modeled creep behaviors were compared with those obtained by microindentation experiments in previous studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.