Evidence map›Paper›PMID 39858677›Full record

ArticleMicromachines2024

Laser Welding of Micro-Wire Stent Electrode as a Minimally Invasive Endovascular Neural Interface.

Bo Wen, Liang Shen, Xiaoyang Kang

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Bo WenLaboratory for Neural Interface and Brain Computer Interface, Engineering Research Center of AI & Robotics, Ministry of Education, Shanghai Engineering Research Center of AI & Robotics, MOE Frontiers Center for Brain Science, State Key Laboratory of Medical Neurobiology, Institute of AI & Robotics, Academy for Engineering & Technology, Fudan University, Shanghai 200433, China.
Liang ShenLaboratory for Neural Interface and Brain Computer Interface, Engineering Research Center of AI & Robotics, Ministry of Education, Shanghai Engineering Research Center of AI & Robotics, MOE Frontiers Center for Brain Science, State Key Laboratory of Medical Neurobiology, Institute of AI & Robotics, Academy for Engineering & Technology, Fudan University, Shanghai 200433, China.
Xiaoyang KangLaboratory for Neural Interface and Brain Computer Interface, Engineering Research Center of AI & Robotics, Ministry of Education, Shanghai Engineering Research Center of AI & Robotics, MOE Frontiers Center for Brain Science, State Key Laboratory of Medical Neurobiology, Institute of AI & Robotics, Academy for Engineering & Technology, Fudan University, Shanghai 200433, China.ORCID 0000-0003-4372-9531

Funding

National Key Research and Development Program of China 2021YFC0122700National Natural Science Foundation of China 61904038Shanghai Municipal Science and Technology Major Project 2021SHZDZX0103
6 · The paper itself

Abstract

Minimally invasive endovascular stent electrodes are an emerging technology in neural engineering, designed to minimize the damage to neural tissue. However, conventional stent electrodes often rely on resistive welding and are relatively bulky, restricting their use primarily to large animals or thick blood vessels. In this study, the feasibility is explored of fabricating a laser welding stent electrode as small as 300 μm. A high-precision laser welding technique was developed to join micro-wire electrodes without compromising structural integrity or performance. To ensure consistent results, a novel micro-wire welding with platinum pad method was introduced during the welding process. The fabricated electrodes were integrated with stent structures and subjected to detailed electrochemical performance testing to evaluate their potential as neural interface components. The laser-welded endovascular stent electrodes exhibited excellent electrochemical properties, including low impedance and stable charge transfer capabilities. At the same time, in this study, a simulation is conducted of the electrode distribution and arrangement on the stent structure, optimizing the utilization of the available surface area for enhanced functionality. These results demonstrate the potential of the fabricated electrodes for high-performance neural interfacing in endovascular applications. The approach provided a promising solution for advancing endovascular neural engineering technologies, particularly in applications requiring compact electrode designs.

Indexed as

electrochemical impedance spectroscopy (EIS)endovascular stent electrodelaser weldingminimally invasive brain–computer interface

Identifiers

PMID39858677
PMCPMC11767702

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.