Evidence map›Paper›PMID 39856481›Full record

ArticleDigestive diseases and sciences2025

Endoscopic Stenting of a Fully Covered Self-Expandable Metal Stent with a Hole in Each Cavity in Malignant Hilar Biliary Obstruction: A Preclinical Proof-of-Concept Study and Initial Human Experience.

Jungnam Lee, Seok Jeong, Don Haeng Lee, Jung-Hyun Lim, Makoto Kobayashi, Mamoru Takenaka, Chang-Il Kwon

Abstract readCase Reports
PubMed Publisher
In one paragraph

Article in Digestive diseases and sciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jungnam LeeDivision of Gastroenterology, Department of Internal Medicine, Inha University Hospital, Inha University College of Medicine, Incheon, Republic of Korea.
Seok JeongDivision of Gastroenterology, Department of Internal Medicine, Inha University Hospital, Inha University College of Medicine, Incheon, Republic of Korea. inos@inha.ac.kr.
Don Haeng LeeDivision of Gastroenterology, Department of Internal Medicine, Inha University Hospital, Inha University College of Medicine, Incheon, Republic of Korea.
Jung-Hyun LimDivision of Gastroenterology, Department of Internal Medicine, Inha University Hospital, Inha University College of Medicine, Incheon, Republic of Korea.
Makoto KobayashiDepartment of Gastroenterology, Yokkaichi Municipal Hospital, Yokkaichi, Japan.
Mamoru TakenakaDepartment of Gastroenterology and Hepatology, Faculty of Medicine, Kindai University, Osaka-Sayama, Japan.
Chang-Il KwonDigestive Disease Center, Department of Internal Medicine, CHA Bundang Medical Center, CHA University, Seongnam, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

aimStent placement for biliary drainage in patients with malignant hilar biliary obstruction (MHBO) has been a topic of long-standing debate, and the best approach remains controversial. Therefore, we aimed to evaluate the efficacy, safety, and removability of multi-hole fully covered self-expandable metal stents (MH-FCSEMSs) in a preclinical experiment using swine hilar bile duct obstruction (HBDO) models and to assess the feasibility and safety of stent placement in patients with MHBO.

methodsThree minipigs underwent endoscopic retrograde cholangiopancreatography (ERCP)-guided endobiliary-radio frequency ablation (EB-RFA) to establish Bismuth type II hilar bile duct stenosis models. Four weeks after EB-RFA, 10-mm diameter and 4-cm length MH-FCSEMSs were endoscopically inserted into the left intrahepatic bile duct of the models. Stent patency and migration, as well as adverse events including cholangitis and endoscopic stent removability, were assessed three months after stent placement. Additionally, clinical applications of MH-FCSEMS were performed in two patients with MHBO to determine feasibility, safety, and stent patency.

resultsMH-FCSEMSs were successfully inserted into the left main intrahepatic bile duct and common hepatic duct of the models under ERCP in all three animals without any technical difficulties. Cholangiograms performed 12 weeks after MH-FCSEMS placement showed no stent migration, and all were successfully removed from the animal models. The functional success rate, defined as a decrease in serum total bilirubin level of more than 50% at 12 weeks after stent placement, was 100%. Moreover, MH-FCSEMSs were successfully inserted in two patients with hilar cholangiocarcinoma. The procedures were technically feasible, and no major periprocedural complications were noted.

conclusionThe preliminary long-term results of both preclinical and clinical pilot studies suggest that endoscopic biliary drainage using MH-FCSEMS may be a safe and effective treatment option for stenting and stent revision in the management of HBDO. Further studies comparing clinical outcomes to those of MH-FCSEMS without multi-hole in malignant hilar biliary obstruction will be needed to verify the clinical benefits.

Indexed as

Bile Duct NeoplasmsCholangiopancreatography, Endoscopic RetrogradeCholestasisSelf Expandable Metallic StentsAgedAnimalsDisease Models, AnimalDrainageFeasibility StudiesFemaleHumansMaleMiddle AgedPilot ProjectsProof of Concept StudySwineFully covered self-expandable metal stentHilar cholangiocarcinomaMalignant hilar biliary obstructionRadio-frequency ablation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked