Evidence map›Paper›PMID 39856470›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2025

Postoperative accuracy quantification of corrective osteotomies: standardisation of Q3D-CT methodology.

Sander J C Tabernée Heijtmeijer, Anne M L Meesters, Nico J J Verdonschot, Paul C Jutte, Job N Doornberg, Peter A J Pijpker, Joep Kraeima

Abstract read
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sander J C Tabernée Heijtmeijer3D-Lab, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands. s.j.c.tabernee.heijtmeijer@umcg.nl.ORCID http://orcid.org/0000-0001-9566-5133
Anne M L Meesters3D-Lab, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands.ORCID http://orcid.org/0000-0001-6882-0054
Nico J J VerdonschotDepartment of Biomechanical Engineering, University of Twente, Enschede, The Netherlands.ORCID http://orcid.org/0000-0002-7531-6523
Paul C JutteDepartment of Orthopaedics, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands.ORCID http://orcid.org/0000-0002-6022-2807
Job N DoornbergDepartment of Orthopaedics, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands.ORCID http://orcid.org/0000-0002-1270-2742
Peter A J Pijpker3D-Lab, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands.ORCID http://orcid.org/0000-0001-9543-1097
Joep Kraeima3D-Lab, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands.ORCID http://orcid.org/0000-0001-8527-960X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCurrently, no gold standard exists for 3D analysis of virtually planned surgery accuracy postoperatively. The aim of this study was to present a new, validated and standardised methodology for 3D postoperative assessment of surgical accuracy in patients undergoing 3D virtually planned and guided corrective osteotomies.

methodsAll patients who underwent 3D planned corrective osteotomy in 2021-2022 at our center with a postoperative CT were included. Postoperative surgical outcome was analysed with a postoperative CT and compared to the preoperative virtual surgical planning to determine achieved accuracy. Validation of the analysis was performed by evaluating the individual assessment of six experienced observers. A postoperative quantification was performed according to the proposed innovative methodology based on rotation axes of a virtual postoperative bone model aligned to the virtual preoperative bone model and virtual surgical planned bone model. To evaluate the intra-observer variability, one observer performed the assessment twice.

resultsQuantification of 13 patients according resulted in measurements with a median range (and its interquartile range) for 3D translation of: 2.43 mm (3.17), for the angle deviations: 3D rotation, 2D coronal, 2D sagittal and 2D axial were: 0.66° (1.66°), 0.74° (0.44°), 0.99° (1.27°), 2.37° (5.00°), respectively. The inter- and intraobserver reliability established with the Intraclass correlation coefficient was for all measurements excellent (> 0.76).

conclusionThe proposed 3D CT technique provides an significant more accurate and objective method for assessment of surgical outcome of a guided corrective osteotomy. The present proposed novel methodology showed excellent inter- and intra-observer reliability with clinically acceptable absolute surgical outcome measurements.

Indexed as

Imaging, Three-DimensionalOsteotomySurgery, Computer-AssistedTomography, X-Ray ComputedAdultFemaleHumansMaleMiddle AgedPostoperative PeriodReproducibility of Results3D technologyAccuracyOsteotomyPatient-specificValidationVirtual surgical planning

Identifiers

PMID39856470
PMCPMC11761794

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.