ArticlePLOS global public health2025
Assessment of scattered and leakage radiation from ultra-portable X-ray systems in chest imaging: An independent study.
Article in PLOS global public health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- A public-private partnership for facility-based tuberculosis screening using chest radiographs, Viet Nam.Bulletin of the World Health Organization · 2026Article
- Real-Time Fluorescence-Based COVID-19 Diagnosis Using a Lightweight Deep Learning System.Sensors (Basel, Switzerland) · 2026Article
- AI X-ray for tuberculosis screening in remote Nepal: Benefits and challenges from a doctor's perspective.Journal of public health research · 2025Article
- AI-Driven Advances in Low-Dose Imaging and Enhancement-A Review.Diagnostics (Basel, Switzerland) · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Ultraportable (UP) X-ray devices are ideal to use in community-based settings, particularly for chest X-ray (CXR) screening of tuberculosis (TB). Unfortunately, there is insufficient guidance on the radiation safety of these devices. This study aims to determine the radiation dose by UP X-ray devices to both the public and radiographers compared to international dose limits. Radiation dose measurements were performed with four UP X-ray devices that met international criteria, utilizing a clinically representative CXR set-up made with a thorax phantom. Scatter and leakage radiation dose were measured at various positions surrounding the phantom and X-ray tube, respectively. These measurements were used to calculate yearly radiation doses for different scenarios based on the median of all UP X-ray devices. From the yearly scatter doses, the minimum distances from the phantom needed to stay below the international public dose limit (1 mSv/year) were calculated. This distance was longest in the direction back towards the X-ray tube and shortest to the left/right sides of the phantom, e.g., 4.5 m and 2.5 m resp. when performing 50 exams/day, at 90 kV, 2.5 mAs and source skin distance (SSD) 1 m. Additional calculations including leakage radiation were conducted at a typical radiographer position (i.e., behind the X-ray tube), with a correction factor for wearing a lead apron. At 2 m behind the X-ray tube, a radiographer wearing a lead apron could perform 106 exams/day at 2.5 mAs and 29 exams/day at 10 mAs (90 kV, SSD 1 m), while keeping his/her radiation dose below the public dose limit (1 mSv/year) and well below the radiographer dose limit (20 mSv/year). In most CXR screening scenarios, the radiation dose of UP X-ray devices can be kept below 1 mSv/year by employing basic radiation safety rules on time, distance and shielding and using appropriate CXR exposure parameters.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.