Evidence map›Paper›PMID 39854340›Full record

ArticlePloS one2025

Evaluating the performance of a new ergonomic laparoscopic needle holder for intracorporeal suturing.

Arturo Minor-Martínez, Ricardo Manuel Ordorica-Flores, Juan Ramón Mota-Carmona, Iván Tlacaélel Franco-González, Jesús Tapia Jurado, Fernando Pérez-Escamirosa

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Arturo Minor-MartínezDepartamento de Ingeniería Eléctrica, Sección de Bioelectrónica, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Ciudad de México, México.
Ricardo Manuel Ordorica-FloresServicio de Cirugía Endoscópica, Hospital Infantil de México Federico Gómez, Ciudad de México, México.
Juan Ramón Mota-CarmonaDepartamento de Ingeniería Eléctrica, Sección de Bioelectrónica, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Ciudad de México, México.
Iván Tlacaélel Franco-GonzálezDepartamento de Ingeniería Eléctrica, Sección de Bioelectrónica, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Ciudad de México, México.
Jesús Tapia JuradoDepartamento de Cirugía, Facultad de Medicina, Universidad Nacional Autónoma de México (UNAM), Ciudad de México, México.
Fernando Pérez-EscamirosaInstituto de Ciencias Aplicadas y Tecnología (ICAT), Universidad Nacional Autónoma de México (UNAM), Ciudad de México, México.ORCID 0000-0001-7886-8692

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In laparoscopy, the absence of ergonomics in the instruments affects the performance and efficiency of the surgeon, increasing the likelihood of developing musculoskeletal injuries. This article presents the development of a laparoscopic needle holder with an ergonomic handle and the experience in its use with surgeons in the intracorporeal suturing task. The handle of the laparoscopic needle holder consists of a semi-spherical piece that easily adapts to the palm of the surgeon's hand and improves the posture and ergonomics of the wrist, allowing the direct transmission of rotational movements around the longitudinal axis of the instrument towards the tip. Moreover, a spring-loaded mechanism allows the tip of the tool to be opened and closed in a normally closed configuration, with enough pressure to hold different surgical needles. Twenty-two pediatric surgery surgeons and residents, without upper extremity musculoskeletal disorders, participated in this study. Each participant performed the intracorporeal suturing task using two laparoscopic needle holders (conventional and with ergonomic handle) in a laparoscopic simulator. Motion data from both instruments were captured and the performance was assessed by means of 16 motion analysis parameters (MAPs). The performance of the residents improved markedly using the laparoscopic needle holder with ergonomic handle, obtaining statistically significant differences in 10 MAPs evaluated. The comparison of the results of each instrument showed that this ergonomic laparoscopic needle holder stood out over the conventional tool, improving psychomotor skills and the ability to control the angular position and rotational movements of the instrument on its own axis, indispensable for intracorporeal suturing. The innovative design of the laparoscopic needle holder with ergonomic handle allows for better transfer of rotational movements from the surgeon's hand directly with the longitudinal axis to the tip, reducing extreme wrist positions and excessive effort to open and close the tip of the instrument during intracorporeal suturing.

Indexed as

ErgonomicsLaparoscopyNeedlesSuture TechniquesAdultEquipment DesignFemaleHumansMaleSurgeons

Identifiers

PMID39854340
PMCPMC11759353

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.