Evidence map›Paper›PMID 39853447›Full record

ArticleJournal of materials science. Materials in medicine2025

Anodized Ti6Al4V-ELI, electroplated with copper is bactericidal against Staphylococcus aureus and enhances macrophage phagocytosis.

Paula Milena Giraldo-Osorno, Adam Benedict Turner, Sebastião Mollet Barros, Robin Büscher, Simone Guttau, Farah Asa'ad, Margarita Trobos, Anders Palmquist

Abstract read
In one paragraph

Article in Journal of materials science. Materials in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. In Vitro Antibacterial Efficacy of a New TiONanomaterials (Basel, Switzerland) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Paula Milena Giraldo-Osorno *Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Adam Benedict Turner *Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Sebastião Mollet Barros *Stryker Trauma Gmbh, Schönkirchen, Germany.
Robin BüscherStryker Trauma Gmbh, Schönkirchen, Germany.
Simone GuttauStryker Trauma Gmbh, Schönkirchen, Germany.
Farah Asa'adDepartment of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Margarita TrobosDepartment of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden. margarita.trobos@biomaterials.gu.se.
Anders PalmquistDepartment of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden. anders.palmquist@biomaterials.gu.se.ORCID http://orcid.org/0000-0002-6974-2577

Funding

ALF ALFGBG-978896H2020 Marie Skłodowska-Curie Actions 861046IngaBritt och Arne Lundbergs Forskningsstiftelse LU2021-0048Vetenskapsrådet 2020-04715
6 · The paper itself

Abstract

Implants aim to restore skeletal dysfunction associated with ageing and trauma, yet infection and ineffective immune responses can lead to failure. This project characterized the microbiological and host cell responses to titanium alloy with or without electroplated metallic copper. Bacterial viability counting and scanning electron microscopy quantified and visualized the direct and indirect bactericidal effects of the Cu-electroplated titanium (Cu-Ep-Ti) against two different Staphylococcus aureus strains. Human THP-1 macrophage adhesion and viability was analyzed, along with phagocytosis. Results showed potent antimicrobial activity alongside promising host-immunomodulatory properties. Direct and indirect exposure to Cu-Ep-Ti produced potent bactericidal effects resulting in 94-100% reductions in bacterial viability at 24 h, with complete eradication in some cases. As expected, cytotoxicity was observed in THP-1 macrophages without media exchange, though when media was exchanged at 8, 24 and 48 h cell viability was equivalent to Control-Ti. Interestingly macrophages adhered to the copper material or grown in the presence of copper ions showed 7-fold increase in phagocytosis of S. aureus bioparticles compared to Control-Ti, suggesting a dual bactericidal and host immunomodulatory mechanism. In conclusion, this Cu-electroplated Ti biomaterial can limit bacterial contamination on the implant surface, whilst simultaneously promoting a beneficial antimicrobial immune response.

Indexed as

Anti-Bacterial AgentsCopperMacrophagesPhagocytosisStaphylococcus aureusTitaniumAlloysBiocompatible MaterialsCell LineCell SurvivalElectrodesHumansMaterials TestingProstheses and ImplantsAlloysAnti-Bacterial AgentsBiocompatible MaterialsCopperTitaniumtitanium alloy (TiAl6V4)

Identifiers

PMID39853447
PMCPMC11761993

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.