Evidence map›Paper›PMID 39853437›Full record

Observational studyActa neurochirurgica2025

A new 3D full-body scanner analyzing the sagittal and coronal balance of the adult spine: a preliminary prospective observational study.

Tae Hoon Kang, Seokin Jang, Inwook Seo, Minseok Choi, Yongsoo Park, Yohan Lee, Jae Hyup Lee, Minjoon Cho

Abstract readObservational Study
In one paragraph

Observational study in Acta neurochirurgica, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tae Hoon KangDepartment of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20 Boramae-Ro 5-Gil, Dongjak-Gu, Seoul, Republic of Korea.
Seokin JangDepartment of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20 Boramae-Ro 5-Gil, Dongjak-Gu, Seoul, Republic of Korea.
Inwook SeoDepartment of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20 Boramae-Ro 5-Gil, Dongjak-Gu, Seoul, Republic of Korea.
Minseok ChoiDepartment of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20 Boramae-Ro 5-Gil, Dongjak-Gu, Seoul, Republic of Korea.
Yongsoo ParkMedi Help Line Co, Ltd, 131, Toegye-ro, Jung-gu, Seoul, South Korea.
Yohan LeeDepartment of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20 Boramae-Ro 5-Gil, Dongjak-Gu, Seoul, Republic of Korea.
Jae Hyup LeeDepartment of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20 Boramae-Ro 5-Gil, Dongjak-Gu, Seoul, Republic of Korea.
Minjoon ChoDepartment of Orthopaedic Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20 Boramae-Ro 5-Gil, Dongjak-Gu, Seoul, Republic of Korea. torto83@snu.ac.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe degenerative spondylosis can cause the difficulty in maintaining sagittal and coronal alignment of spine, and X-ray parameters are the gold standard to analyze the malalignment. This study aimed to develop a new 3D full body scanner to analyze the spinal balance and compare it to X-ray parameters.

methodsNinety-seven adult participants who suffer degenerative spondylosis underwent 3D full body scanning, whole spine X-rays, clinical questionnaires and body composition analyses. The 5 inflection points (ear, shoulder, hip, knee, ankle) of the 3D scanner in the sagittal plane were automatically labeled by an AI algorithm. Three concepts are created including "the angle between two points with respect to the plumb line", "the horizontal distances between two points in the sagittal plane" and "the angle between three points". For the coronal plane, the shoulder gradient was analyzed. X-ray parameters of cervical, thoracolumbar and whole spine sagittal balance and coronal balances were compared. The body composition data and clinical questionnaire scores were compared to x-ray and 3D scanner parameters.

resultsThe correlation coefficient (C.C.) of dAB_hor (horizontal distance between ear and shoulder in the sagittal plane) and C2-C7 SVA was 0.478 (p-value < 0.001). The C.C. of aAC_sag (sagittal angle of ear-hip from the plumb line) and ODHA was 0.336 (p < 0.001). About coronal balance, the C.C. of shoulder gradient and clavicle angle from x-ray was 0.373 (p < 0.001). The C.C.s were merely affected by body composition data. But in multiple regression analysis, BMI affected 3D scanner data. Clinical symptoms showed correlations with aBCD(shoulder-hip-knee) and aCDE(hip-knee-ankle angle), which may reflect a compensatory pelvic retroversion and knee flexion for positive sagittal imbalance.

conclusionsThis new 3D scanner has some strengths like radiation-free methods, correlation with x-ray parameters and clinical symptoms, independence to body composition data, and possibility of analyzing dynamic spine balance.

Indexed as

Imaging, Three-DimensionalPostural BalanceSpineSpondylosisWhole Body ImagingAdultAgedFemaleHumansMaleMiddle AgedProspective Studies3D full body scannerAdult spine deformityAnthropometryCompensatory mechanism of positive sagittal balanceDynamic spine balanceSagittal and coronal balance of the adult spine

Identifiers

PMID39853437
PMCPMC11761465

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.