Evidence map›Paper›PMID 39852109›Full record

ArticleBiosensors2025

Rapid Detection of microRNA-122 in Serum and Finger Blood Using a Lateral Flow Nucleic Acid Biosensor.

Min Zhang, Meijing Ma, Jiahui Wang, Yurui Zhou, Xueji Zhang, Guodong Liu

Abstract read
In one paragraph

Article in Biosensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Min ZhangSchool of Chemistry and Chemical Engineering, Linyi University, Linyi 276005, China.
Meijing MaSchool of Chemistry and Chemical Engineering, Linyi University, Linyi 276005, China.
Jiahui WangSchool of Chemistry and Chemical Engineering, Linyi University, Linyi 276005, China.
Yurui ZhouSchool of Chemistry and Chemical Engineering, Linyi University, Linyi 276005, China.
Xueji ZhangMarshall Laboratory of Biomedical Engineering, Research Center for Biosensor and Nanotheranostic, School of Biomedical Engineering, Shenzhen University, Shenzhen 518060, China.
Guodong LiuSchool of Chemistry and Chemical Engineering, Linyi University, Linyi 276005, China.ORCID 0000-0003-1063-208X

Funding

Linyi Unversity Z6122047National Key Research and Development Program of the Ministry of Science and Technology 2022YFB3207200
6 · The paper itself

Abstract

MicroRNA122 (miR-122) is a microRNA that is highly expressed in hepatocytes and has been identified as a prospective therapeutic target and biomarker for liver injury. An expanding body of research has demonstrated that miR-122 is a critical regulator in both the initiation and progression of a wide range of liver diseases. Traditional methods for detecting miR-122 mainly include Northern blotting and qRT-PCR, but they are technically complex and cumbersome, requiring expensive instruments and high technical requirements. In this paper, we present a novel rapid testing method utilizing a lateral flow nucleic acid biosensor (LFNAB) for the sensitive and time-efficient detection of miR-122. This approach offers several advantages, including a high specificity for miR-122, the ability to detect low concentrations of the target molecule, and a significantly reduced testing time compared to conventional detection methods. In this study, a thiol-modified single-stranded detection DNA probe (Det-DNA), a biotinylated single-stranded capture DNA probe (Cap-DNA), and a biotinylated single-stranded control DNA probe (Con-DNA) are used to construct the LFNAB. A gold nanoparticle (AuNP) is a colored tag, which is used to label the Det-DNA probe. The principle of detecting miR-122 is based on dual DNA-miRNA hybridization reactions on the LFNAB to form sandwich-type AuNP-Det-DNA-miR-122-Cap-DNA complexes, which are captured on the test area of LFNAB for visualization and quantification. After systematic optimization of conditions of experiment, the response of LFNAB was highly linear within the scope of 0 pM-100 pM miR-122, and the detection limit in 15 min was 3.90 pM. The use of LFNAB to detect miR-122 in serum and fingertip blood has yielded satisfactory results. This successful application indicates the effectiveness of LFNAB in detecting miR-122 in both serum and fingertip blood samples, showcasing its potential utility in clinical and research settings for assessing miR-122 levels in different biological samples.

Indexed as

Biosensing TechniquesMicroRNAsDNA ProbesGoldHumansLimit of DetectionMetal NanoparticlesDNA ProbesGoldMicroRNAsMIRN122 microRNA, humanbiosensorsgold nanoparticleslateral flowmiR-122visual detection

Identifiers

PMID39852109
PMCPMC11764104

What OpenQuestion holds

Textmetadata
LicenceCC BY