Evidence map›Paper›PMID 39852074›Full record

ArticleBiosensors2025

A Truncated Multi-Thiol Aptamer-Based SARS-CoV-2 Electrochemical Biosensor: Towards Variant-Specific Point-of-Care Detection with Optimized Fabrication.

Sergio Roberto Molina Ramirez, Nafiseh Samiseresht, Mateo Alejandro Martínez-Roque, Ferdinando Catania, Kevin Graef, Martin Rabe, Andreas Offenhäusser, Dirk Mayer, Gabriela Figueroa-Miranda

Abstract read
In one paragraph

Article in Biosensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Sergio Roberto Molina RamirezInstitute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany.ORCID 0000-0002-0504-9263
Nafiseh SamisereshtDepartment of Interface Chemistry and Surface Engineering, Max Planck Institute for Sustainable Materials GmbH, 40237 Düsseldorf, Germany.ORCID 0009-0007-6532-4603
Mateo Alejandro Martínez-RoqueInstitute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany.ORCID 0000-0001-5401-4211
Ferdinando CataniaInstitute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany.
Kevin GraefInstitute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany.ORCID 0009-0005-3160-0054
Martin RabeDepartment of Interface Chemistry and Surface Engineering, Max Planck Institute for Sustainable Materials GmbH, 40237 Düsseldorf, Germany.ORCID 0000-0002-0503-5355
Andreas OffenhäusserInstitute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany.ORCID 0000-0001-6143-2702
Dirk MayerInstitute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany.ORCID 0000-0003-1296-8265
Gabriela Figueroa-MirandaInstitute of Biological Information Processing, Bioelectronics (IBI-3), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany.ORCID 0000-0002-7056-5547

Funding

Deutsche Forschungsgemeinschaft EXC 2033 - 390677874 - RESOLVFederal Ministry of Education and Research 03VP11340
6 · The paper itself

Abstract

With the goal of fast and accurate diagnosis of infectious diseases, this study presents a novel electrochemical biosensor that employs a refined aptamer (C9t) for the detection of spike (S) protein SARS-CoV-2 variants in a flexible multielectrode aptasensor array with PoC capabilities. Two aptamer modifications were employed: removing the primer binding sites and including two dithiol phosphoramidite anchor molecules. Thus, reducing fabrication time from 24 to 3 h and increasing the stability and sparseness for multi-thiol aptasensors compared to a standard aptasensor using single thiols, without a reduction in aptamer density. The biosensor fabrication, optimization, and detection were verified in detail by electrochemistry, QCM-D, SPR, and XPS. The analyte-receptor binding was further confirmed spectroscopically at the level of individual molecules by AFM-IR. The aptasensor possesses a low limit of detection (8.0 fg/mL), the highest sensitivity reported for S protein (209.5 signal per concentration decade), and a wide dynamic detection range (8.0 fg/mL-38 ng/mL) in nasopharyngeal samples, covering the clinically relevant range. Furthermore, the C9t aptasensor showed high selectivity for SARS-CoV-2 S proteins over biomarkers for MERS-CoV, RSV, and Influenza. Even more, it showed a three times higher sensitivity for the Omicron in comparison to the Wuhan strain (wild type), alpha, and beta variants of the SARS-CoV-2 virus. Those results demonstrate the creation of an affordable and variant-selective refined C9t aptasensor that outperformed current rapid diagnosis tests.

Indexed as

Aptamers, NucleotideBiosensing TechniquesCOVID-19Electrochemical TechniquesSARS-CoV-2Spike Glycoprotein, CoronavirusHumansLimit of DetectionPoint-of-Care SystemsSulfhydryl CompoundsAptamers, NucleotideSpike Glycoprotein, Coronavirusspike protein, SARS-CoV-2Sulfhydryl Compoundsaptamer truncationelectrochemical aptasensormulti-thiolSARS-CoV-2S protein

Identifiers

PMID39852074
PMCPMC11763500

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.