Evidence map›Paper›PMID 39852052›Full record

ArticleBiosensors2024

Microspectrometer-Enabled Real-Time Concentration Monitoring in the Microfluidic Protein Enrichment Chip.

Dong-Li Li, Wen-Shu Huang, Yi Hung Wu, Chun-Ping Jen

Abstract read
In one paragraph

Article in Biosensors, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Dong-Li LiFisheries College, Jimei University, Xiamen 361021, China.
Wen-Shu HuangFisheries College, Jimei University, Xiamen 361021, China.
Yi Hung WuDepartment of Mechanical Engineering and Advanced Institute of Manufacturing for High-Tech Innovations, National Chung Cheng University, Chia-Yi 62102, Taiwan.
Chun-Ping JenDepartment of Mechanical Engineering and Advanced Institute of Manufacturing for High-Tech Innovations, National Chung Cheng University, Chia-Yi 62102, Taiwan.ORCID 0000-0001-5558-5817

Funding

National Science and Technology Council of the Republic of China (Taiwan) NSTC 113-2221-E-194-018
6 · The paper itself

Abstract

This study presents a novel microspectrometer-integrated microfluidic system for real-time protein concentration monitoring. The device employs electrokinetic principles for efficient protein preconcentration in a PDMS and Nafion film channel. Using FITC-labeled BSA as a model protein, the system demonstrated a linear correlation between protein concentration and absorbance at 491 nm. Notably, it achieved a 833-fold concentration increase from an initial 10 nM within 20 min. The compact microspectrometer system offers enhanced accuracy and sensitivity compared to traditional fluorescence microscopy methods. This innovation presents a promising solution for portable and point-of-care diagnostic applications, facilitating timely disease detection and monitoring. The findings highlight the potential for this technology to advance protein analysis and biomarker discovery in clinical settings, potentially improving patient outcomes through enhanced diagnostic capabilities.

Indexed as

Biosensing TechniquesLab-On-A-Chip DevicesMicrofluidic Analytical TechniquesProteinsAnimalsMicrofluidicsSerum Albumin, BovineProteinsSerum Albumin, Bovinefluorescencemicrofluidic chipsmicrospectrometerpreconcentrationprotein detection

Identifiers

PMID39852052
PMCPMC11763946

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.