ArticleJapanese journal of radiology2025

Usefulness of four-dimensional noise reduction filtering using a similarity algorithm in low-dose dynamic computed tomography for the evaluation of breast cancer: a preliminary study.

Daichi Uraoka, Megumi Matsuda, Yuki Tanabe, Naoto Kawaguchi, Chihiro Nishiyama, Ayaka Okada, Koichiro Uda, Hiroshi Suekuni, Hikaru Nishiyama, Yoshiaki Kamei and 4 more

Abstract read
In one paragraph

Article in Japanese journal of radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Daichi UraokaDepartment of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Megumi MatsudaDepartment of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan. megumi.takechi@gmail.com.ORCID http://orcid.org/0000-0002-5667-4448
Yuki TanabeDepartment of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Naoto KawaguchiDepartment of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Chihiro NishiyamaDepartment of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Ayaka OkadaDepartment of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Koichiro UdaDepartment of Radiology, Ehime Prefectural Central Hospital, Kasugamachi, Matsuyama, Ehime, 790-0024, Japan.
Hiroshi SuekuniDepartment of Radiology, Ehime University Hospital, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Hikaru NishiyamaDepartment of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Yoshiaki KameiBreast Center, Ehime University Hospital, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Mie KurataDepartment of Pathology, Ehime University Proteo-Science Center, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Riko KitazawaDivision of Diagnostic Pathology, Ehime University Hospital, Shitsukawa, Toon, Ehime, 791-0295, Japan.
Shota NakanoCanon Medical Systems Corporation, Shimoishigami, Otawara, Tochigi, 324-8550, Japan.
Teruhito KidoDepartment of Radiology, Ehime University Graduate School of Medicine, Shitsukawa, Toon, Ehime, 791-0295, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the effects of four-dimensional noise reduction filtering using a similarity algorithm (4D-SF) on the image quality and tumor visibility of low-dose dynamic computed tomography (CT) in evaluating breast cancer. MATERIALS AND

methodsThirty-four patients with 38 lesions who underwent low-dose dynamic breast CT and were pathologically diagnosed with breast cancer were enrolled. Dynamic CT images were reconstructed using iterative reconstruction alone or in combination with 4D-SF. We selected the peak enhancement phase image of breast cancer for each patient for quantitative and qualitative evaluations of image quality and measurement of the maximum diameter of breast cancer. The signal-to-noise and contrast-to-noise ratios were calculated for quantitative evaluation. The maximum diameters of the breast cancer were measured from the images obtained with and without 4D-SF (4D-SF ±) (size-4D-SF + and size-4D-SF-) and for the pathological specimen (size-PS) and compared.

resultsThe median and interquartile ranges of the signal-to-noise ratio [4D-SF-: 3.03 (2.54-4.17) vs 4D-SF + : 5.52 (4.75-6.66)] and contrast-to-noise ratio [4D-SF-: 2.88 (2.00-3.60) vs 4D-SF + : 7.84 (4.65-10.35)] were significantly higher for 4D-SF + than for 4D-SF- (p < 0.001). The overall image quality (Observer 1, p < 0.001; Observer 2, p < 0.001) and tumor margin sharpness scores (Observer 1, p = 0.003; Observer 2, p < 0.001) were significantly higher for 4D-SF + than for 4D-SF-. The tumor contrast scores for 4D-SF + and 4D-SF- were not significantly different (Observers 1, 2; p = 0.083). Size-4D-SF- was significantly smaller than size-PS (p < 0.001); size-4D-SF + was also smaller than size-PS, but the difference was not significant (p = 0.088). The Spearman's rank correlation coefficient was 0.65 for size-PS and size-4D-SF- and 0.77 for size-PS and size-4D-SF + .

conclusionThe 4D-SF can improve the image quality and tumor visibility of low-dose dynamic CT in evaluating breast cancer extent due to noise reduction.

Indexed as

AlgorithmsBreast NeoplasmsFour-Dimensional Computed TomographyRadiographic Image Interpretation, Computer-AssistedTomography, X-Ray ComputedAdultAgedAged, 80 and overBreastContrast MediaFemaleHumansMiddle AgedRadiation DosageRetrospective StudiesSignal-To-Noise RatioContrast MediaBreast cancerComputed tomographyFour-dimensional noise reduction filtering using a similarity algorithmRadiation dose reduction

Identifiers

PMID39849240
PMCPMC12053336

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.