ArticleACS applied materials & interfaces2025
Carboxylate-Terminated Electrode Surfaces Improve the Performance of Electrochemical Aptamer-Based Sensors.
Article in ACS applied materials & interfaces, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- A robust Au-C[triple bond, length as m-dash]C anchoring group greatly improves the signal stability of electrochemical aptamer-based sensors forChemical science · 2026Article
- Advancements in Nanomaterial-Based Biosensors for Neuropsychiatric and Neurodegenerative Diagnostics: From Biomarker Discovery to Clinical Translation.Biosensors · 2026Review
- Pilot phase clinical trial of a wearable, electrochemical aptamer-based patch for continuous drug concentration measurement.Nature biotechnology · 2026Article
- Fluorescent modifications in aptamer switches-positional, structural, and neighboring pair effects on sensor performance.Nucleic acids research · 2025Article
- On the Design, Fabrication, and Operation of Electrochemical Aptamer-Based Sensors.ACS sensors · 2025Review
- Cyclooctyne-Functionalized N-Heterocyclic Carbenes for Click Coupling of Sensing Oligonucleotides to Gold Surfaces.ACS sensors · 2025Article
- Capacitive Sensors for Label-Free Detection in High-Ionic-Strength Bodily Fluids: A Review.Biosensors · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Electrochemical aptamer-based (EAB) sensors are a molecular measurement platform that enables the continuous, real-time measurement of a wide range of drugs and biomarkers in situ in the living body. EAB sensors are fabricated by depositing a thiol-modified, target-binding aptamer on the surface of a gold electrode, followed by backfilling with an alkanethiol to form a self-assembled monolayer. And while the majority of previously described EAB sensors have employed hydroxyl-terminated monolayers, a handful of studies have shown that altering the monolayer headgroup can strongly affect sensor performance. Here, using 4 different EAB sensors, we show that the mixed monolayers composed of mixtures of 6-carbon hydroxyl-terminated thiols and varying amounts of either 6- or 8-carbon, carboxylate-terminated thiols lead to improved EAB sensor performance. Specifically, the use of such mixed monolayers enhances the signal gain (the relative change in the signal seen upon target addition) for all tested sensors, often by several fold, both in buffer and whole blood at room temperature or physiological temperatures. Moreover, these improvements in gain are achieved without significant changes in the aptamer affinity or the stability of the resulting sensors. In addition to proving a ready means of improving EAB sensor performance, these results suggest that exploration of the chemistry of the electrode surface employed in such sensors could prove to be a fruitful means of advancing this unique in vivo sensing technology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials