ArticleCureus2024
Evaluation of Male Gonadal Radiation Dose in Abdominal X-ray Examinations: The Impact of Radiographic Projections and Kilovoltage Peak (kVp).
Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In abdominal X-ray examinations, radiosensitive organs such as the gonads within or near the imaging region are at risk of radiation exposure. Minimizing the dose to these organs is crucial to reducing unnecessary radiation. This study utilized optically stimulated luminescence dosimeters (OSLDs) to measure the radiation dose to the male gonads at varying kilovoltage peak (kVp) settings while keeping the milliampere-seconds (mAs) constant across different radiographic projections. A Siemens Multix Top X-ray system (Siemens Healthcare Inc., Erlangen, Germany) was used for imaging, with three kVp settings (81, 83, and 85) and a fixed exposure of 32 mAs. The study employed a RANDO phantom (The Phantom Laboratory, Salem, New York, USA) to simulate human anatomy. The entrance surface dose (ESD) was recorded by placing an OSLD on the phantom's surface corresponding to the gonad location. In contrast, the absorbed dose was measured by positioning the OSLD at the gonadal region inside the phantom. Six abdominal projections were evaluated: anteroposterior (AP) supine, posteroanterior (PA) prone, lateral, AP erect, lateral decubitus, and dorsal decubitus. All imaging was conducted with a source-to-image distance of 100 cm. The dorsal and lateral decubitus positions resulted in relatively higher radiation doses. Conversely, the AP supine, PA prone, lateral, and AP erect positions exhibited lower ESD and absorbed doses. Statistical analysis revealed no significant differences in ESD and absorbed doses for male gonads across the projections. Additionally, an increase in kVp correlated with a reduction in both ESD and absorbed dose. This study emphasizes the critical importance of optimizing kVp settings to minimize radiation exposure to male gonads during abdominal X-ray examinations. It also emphasizes the significant influence of radiographic projections on radiation dose, advocating for careful selection of projections to enhance patient safety. These findings contribute to advancing radiological practices, reducing unnecessary radiation exposure, and improving patient care standards.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials