Evidence map›Paper›PMID 39839192›Full record

ArticleIEEE Biomedical Circuits and Systems Conference : healthcare technology : [proceedings]. IEEE Biomedical Circuits and Systems Conference2024

A Wearable Prototype Measuring PtcCO

Kleo Golemi, Evan Apinis, Isil Isiksalan, Vladimir Vakhter, Ulkuhan Guler

Abstract read
In one paragraph

Article in IEEE Biomedical Circuits and Systems Conference : healthcare technology : [proceedings]. IEEE Biomedical Circuits and Systems Conference, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kleo GolemiDepartment of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 USA.
Evan ApinisDepartment of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 USA.
Isil IsiksalanDepartment of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 USA.
Vladimir VakhterDepartment of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 USA.
Ulkuhan GulerDepartment of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 USA.

Funding

SCH: A Novel Bias-mitigated Multimodal Oxygen MonitorR01HL172293 · NHLBI · WORCESTER POLYTECHNIC INSTITUTE · PI Ulkuhan Guler · 2023 to 2026
$1.1M
Computational Models for Smart CO2 MonitoringR21EB036329 · NIBIB · MICHIGAN STATE UNIVERSITY · PI GULER, ULKUHAN, UNLUTURK, BIGE DENIZ · 2024 to 2024
$374k
NHLBI NIH HHS R01 HL172293NIBIB NIH HHS R21 EB036329
6 · The paper itself

Abstract

The proper functioning of the respiratory system is evaluated by monitoring the exchange of blood oxygen and carbon dioxide. While wearable devices for monitoring both blood oxygen and carbon dioxide are emerging, wearable carbon dioxide monitors remain relatively rare. This paper introduces a novel wearable prototype that integrates the measurement of transcutaneous carbon dioxide and peripheral blood oxygen saturation on a miniaturized custom-designed printed circuit board. The device employs a fluorescent sensing film consisting of two distinct luminophore types and utilizes the time-domain dual lifetime referencing technique to enhance measurement accuracy by mitigating the effects of confounding factors. Thorough testing on human subjects validated the prototype's functionality, comparing its performance against commercial clinical devices. The prototype effectively tracked changes in transcutaneous carbon dioxide induced by hyperventilation, with a resolution as low as 1 mmHg. Additionally, blood oxygen saturation measurements were tested on human subjects to compare our prototypes' performance to that of clinical devices. The results confirm the potential of the proposed novel wearable for prolonged use with minimal maintenance and underscore its significance in advancing wearable health monitoring technologies.

Indexed as

fluorescence sensingnoninvasive blood gas monitoringphysiological monitoringPtcCO2pulse oximeterSpO2t-DLRTranscutaneous carbon dioxide sensing

Identifiers

PMID39839192
PMCPMC11747940

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.