Evidence map›Paper›PMID 39837810›Full record

ArticleLight, science & applications2025

Using light to image millimeter wave based on stacked meta-MEMS chip.

Han Wang, Zhigang Wang, Cheng Gong, Xinyu Li, Tiansheng Cui, Huiqi Jiang, Minghui Deng, Bo Yan, Weiwei Liu

Abstract read
In one paragraph

Article in Light, science & applications, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Han WangInstitute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin, 300350, China.
Zhigang WangSchool of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China.
Cheng GongInstitute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin, 300350, China. gongcheng@nankai.edu.cn.
Xinyu LiInstitute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin, 300350, China.
Tiansheng CuiInstitute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin, 300350, China.
Huiqi JiangInstitute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin, 300350, China.
Minghui DengInstitute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin, 300350, China.
Bo YanSchool of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, 611731, China.
Weiwei LiuInstitute of Modern Optics, Nankai University, Tianjin Key Laboratory of Micro-scale Optical Information Science and Technology, Tianjin, 300350, China.ORCID http://orcid.org/0000-0001-6036-9641

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A stacked metamaterial MEMS (meta-MEMS) chip is proposed, which can perfectly absorb electromagnetic waves, convert them into mechanical energy, drive movement of the optical micro-reflectors array, and detect millimeter waves. It is equivalent to using visible light to image a millimeter wave. The meta-MEMS adopts the design of upper and lower chip separation and then stacking to achieve the "dielectric-resonant-air-ground" structure, reduce the thickness of the metamaterial and MEMS structures, and improve the performance of millimeter wave imaging. For verification, we designed and prepared a 94 GHz meta-MEMS focal plane array chip, in which the sum of the thickness of the metamaterial and MEMS structures is only 1/2500 wavelength, the pixel size is less than 1/3 wavelength, but the absorption rate is as high as 99.8%. Moreover, a light readout module was constructed to test the millimeter wave imaging performance. The results show that the response speed can reach 144 Hz and the lens-less imaging resolution is 1.5 mm.

Identifiers

PMID39837810
PMCPMC11751477

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.