ArticleMedical & biological engineering & computing2025
Microvascular blood flow ultrasound imaging with microbubble-based H-Scan technology.
Article in Medical & biological engineering & computing, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Ultrasound blood flow imaging plays a crucial role in the diagnosis of cardiovascular and cerebrovascular diseases. Conventional ultrafast ultrasound plane-wave imaging techniques have limited capabilities in microvascular imaging. To enhance the quality of blood flow imaging, this study proposes a microbubble-based H-Scan ultrasound imaging technique. This technique utilizes high-order H-Scan to detect the Rayleigh scattering contributed by blood flow and microbubbles at certain concentrations. The detected results are then processed in the B channel using methods such as clutter filtering based on Casorati matrix singular value decomposition (Casorati-SVD). Compared with the control group without H-Scan, the signal-to-noise ratio (SNR) of the experimental group using the microbubble-based H-Scan ultrasound imaging technique was increased by 38.61% on average and the contrast signal-to-noise ratio (CNR) was increased by 39.5% on average. The improved image quality of microvascular flow imaging was visibly enhanced. This method demonstrates significant advantages in enhancing the sensitivity and accuracy of ultrasound blood flow imaging, indicating considerable potential for clinical applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.