Improving Image Quality and Decreasing SAR With High Dielectric Constant Pads in 3 T Fetal MRI.

Zhengyang Zhu, Xunwen Xue, Tang Tang, Chao Luo, Ye Li, Jing Chen, Biyun Xu, Zengping Lin, Xin Zhang, Zhengge Wang and 12 more

Abstract read
In one paragraph

Article in Journal of magnetic resonance imaging : JMRI, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

22 authors.

Zhengyang ZhuDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.ORCID 0000-0001-9916-3480
Xunwen XueDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Tang TangDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Chao LuoLauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
Ye LiLauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
Jing ChenDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Biyun XuMedical Statistics and Analysis Center, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Zengping LinCentral Research Institute, United Imaging Healthcare Group Co., Ltd, Shanghai, China.
Xin ZhangDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Zhengge WangDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Jun ChenDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Jiaming LuDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Wen ZhangDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Xin LiDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Qian ChenDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Zhuoru JiangDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Junxia WangDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Qing HuDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Sven HallerCIMC Geneva, Geneva, Switzerland.
Ming LiDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Chenchen YanDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.
Bing ZhangDepartment of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu, China.ORCID 0000-0002-3953-0290

Funding

2023 Nanjing Health Science and Technology Development of Medicine and Health Research YKK23103National Science and Technology Innovation 2030 2022ZD0211800
6 · The paper itself

Abstract

backgroundAt high magnetic fields, degraded image quality due to dielectric artifacts and elevated specific absorption rate (SAR) are two technical challenges in fetal MRI. PURPOSE: To assess the potential of high dielectric constant (HDC) pad in increasing image quality and decreasing SAR for 3 T fetal MRI. STUDY TYPE: Prospective. FIELD STRENGTH/SEQUENCE: 3 T. Balanced steady-state free precession (bSSFP) and single-shot fast spin-echo (SSFSE). POPULATION: One hundred twenty-eight participants (maternal-age 29.0 ± 3.6, range 20-40; gestational-age 30.3 ± 3.5 weeks, range 22-37 weeks) undertook bSSFP and 40 participants (maternal-age 29.5 ± 3.8, range 19-40; gestational-age 30.4 ± 3.5 weeks, range 23-37 weeks) undertook SSFSE. ASSESSMENT: Patient clinical characteristics were recorded, such as gestational-age, amniotic-fluid-index, abdominal-circumference, body-mass-index, and fetal-presentation. Quantitative Image-quality analysis included signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Qualitative analysis was performed by three radiologists with four-point scale to evaluate overall image quality, dielectric artifact, and diagnostic confidence. Whole-body total SAR was obtained from the vendor workstation. STATISTICAL TESTING: Paired rank sum test was used to analyze the differences in SNR, CNR, overall image quality, dielectric artifact, diagnostic confidence, and SAR with and without HDC pad. Spearman correlation test was used to detect correlations between image quality variable changes and patient clinical characteristics. P values <0.05 were set as statistical significance.

resultsWith HDC pad, SNR and CNR was significantly higher (41.45% increase in SNR, 54.05% increase in CNR on bSSFP; 258.76% increase in SNR, 459.55% increase in CNR on SSFSE). Overall qualitative image quality, dielectric artifact and diagnostic confidence improved significantly. Adding HDC pad significantly reduced Whole-body total SAR (32.60% on bSSFP; 15.40% on SSFSE). There was no significant correlation between image quality variable changes and participant clinical characteristics (P-values ranging from 0.072 to 0.992). DATA

conclusionIn the clinical setting, adding a HDC pad might increase image quality while reducing dielectric artifact and SAR. PLAN LANGUAGE SUMMARY: Dielectric artifacts and elevated SAR are two technical problems in 3T fetal MRI. In a prospective analysis of 168 pregnant participants undertaking 3.0T fetal MRI scanning, high dielectric constant (HDC) pad increased SNR by 41.45%, CNR by 54.05% on bSSFP, and SNR by 258.76%, CNR by 459.55% on SSFSE. Overall image quality, dielectric artifact reduction, and diagnostic confidence assessed by three radiologists was improved. Whole-body total SAR decreased by 32.60% on bSSFP and by 15.40% on SSFSE. These findings suggested that the HDC pad can enhance fetal MRI safety and quality, making it a promising tool for clinical practice. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 5.

Indexed as

FetusImage EnhancementMagnetic Resonance ImagingPrenatal DiagnosisAdultArtifactsFemaleGestational AgeHumansImage Processing, Computer-AssistedPregnancyProspective StudiesReproducibility of ResultsSignal-To-Noise RatioYoung Adultfetal MRIhigh dielectric constantimage qualityspecific absorption rate

Identifiers

PMID39835472
PMCPMC12063766

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.