Evidence map›Paper›PMID 39834697›Full record

ArticleFrontiers in neuroscience2024

NORDIC denoising on VASO data.

Lasse Knudsen, Luca Vizioli, Federico De Martino, Lonike K Faes, Daniel A Handwerker, Steen Moeller, Peter A Bandettini, Laurentius Huber

Abstract read
In one paragraph

Article in Frontiers in neuroscience, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Lasse KnudsenCenter of Functionally Integrative Neuroscience (CFIN), Aarhus University, Aarhus, Denmark.
Luca VizioliCMRR, University of Minnesota, Minneapolis, MN, United States.
Federico De MartinoFPN, Maastricht University, Maastricht, Netherlands.
Lonike K FaesFPN, Maastricht University, Maastricht, Netherlands.
Daniel A HandwerkerSection on Functional Imaging Methods, NIH, National Institute of Mental Health, Bethesda, MD, United States.
Steen MoellerCMRR, University of Minnesota, Minneapolis, MN, United States.
Peter A BandettiniSection on Functional Imaging Methods, NIH, National Institute of Mental Health, Bethesda, MD, United States.
Laurentius HuberFunctional Magnetic Resonance Imaging (FMRI) Core, NIH, National Institute of Mental Health, Bethesda, MD, United States.

Funding

Functional MRI Core FacilityZICMH002884 · NIMH · NATIONAL INSTITUTE OF MENTAL HEALTH · PI BANDETTINI, PETER · 2009 to 2025
$85.5M
Functional MRI Method DevelopmentZIAMH002783 · NIMH · NATIONAL INSTITUTE OF MENTAL HEALTH · PI BANDETTINI, PETER · 2009 to 2025
$38.4M
TRD4 - Ultrahigh Field Engineering and SafetyP41EB027061 · NIBIB · UNIVERSITY OF MINNESOTA · PI Gregory John Metzger, KAMIL UGURBIL · 2019 to 2026
$11.7M
Intramural NIH HHS ZIA MH002783Intramural NIH HHS ZIC MH002884NIBIB NIH HHS P41 EB027061
6 · The paper itself

Abstract

The use of submillimeter resolution functional magnetic resonance imaging (fMRI) is increasing in popularity due to the prospect of studying human brain activation non-invasively at the scale of cortical layers and columns. This method, known as laminar fMRI, is inherently signal-to-noise ratio (SNR)-limited, especially at lower field strengths, with the dominant noise source being of thermal origin. Furthermore, laminar fMRI is challenged with signal displacements due to draining vein effects in conventional gradient-echo blood oxygen level-dependent (BOLD) imaging contrasts. fMRI contrasts such as cerebral blood volume (CBV)-sensitive vascular space occupancy (VASO) sequences have the potential to mitigate draining vein effects. However, VASO comes along with another reduction in detection sensitivity. NOise Reduction with DIstribution Corrected (NORDIC) PCA (principal component analysis) is a denoising technique specifically aimed at suppressing thermal noise, which has proven useful for increasing the SNR of high-resolution functional data. While NORDIC has been examined for BOLD acquisitions, its application to VASO data has been limited, which was the focus of the present study. We present a preliminary analysis to evaluate NORDIC's capability to suppress thermal noise while preserving the VASO signal across a wide parameter space at 3T. For the data presented here, with a proper set of parameters, NORDIC reduced thermal noise with minimal bias on the underlying signal and preserved spatial resolution. Denoising performance was found to vary with different implementation strategies and parameter choices, for which we provide recommendations. We conclude that when applied properly, NORDIC has the potential to overcome the sensitivity limitations of laminar-specific VASO fMRI. Since very few groups currently have 3T VASO data, by sharing our analysis and code, we can compile and compare the effects of NORDIC across a broader range of acquisition parameters and study designs. Such a communal effort will help develop robust recommendations that will increase the utility of laminar fMRI at lower field strengths.

Indexed as

denoisinglaminar fMRINORDICsubmillimeter resolutionVASO

Identifiers

PMID39834697
PMCPMC11743533

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked