ArticleCureus2025
Mid-term Clinical and Radiographic Outcomes of the Actis Total Hip System: A Retrospective Study.
Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Multicentre outcomes of total hip arthroplasty using a novel collared cementless femoral stem.Bone & joint open · 2026Article
- Canal fill and radiographic comparison analysis of novel fully hydroxyapatite coated, variable triple-tapered geometry stems: one-year follow-up after direct anterior approach total hip arthroplasty.Archives of orthopaedic and trauma surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction Implant technology for total hip arthroplasty (THA) was developed to improve hip function and patient satisfaction. Actis (DePuy Synthes, Warsaw, IN, USA) is a short fit-and-fill titanium stem, with a medial-collared and triple-taper (MCTT) geometry, that is fully coated with hydroxyapatite (HA). We evaluated the radiographic and clinical outcomes of the Actis Total Hip System during a mean follow-up of five years. Patients and methods We retrospectively analyzed data from 80 patients (14 male and 66 female, mean age: 65 ± 8.4 years) who underwent primary THA using Actis stems (anterolateral approach, 60 hips; posterior approach, 20 hips). Radiographs were obtained postoperatively and at the time of the final examination. Radiographic assessments included the alignment of the femoral stem, spot welds, stress shielding, cortical hypertrophy, subsidence (>2 mm), radiolucent line, pedestal formation, Dorr type, canal fill ratio (CFR), and stem fixation. Clinical evaluation included the Japanese Orthopaedic Association Hip-Disease Evaluation Questionnaire (JHEQ) and Harris Hip Score (HHS). Results The mean follow-up period was 64.0 ± 6.0 months. No significant differences were observed in the alignment of the femoral components between approaches. Of the 80 hips, 53 (66.3%) showed radiographic signs of stem osseointegration, predominantly in the mid-distal region of the stem at the final follow-up. Multiple logistic regression analysis revealed that younger age and a higher CFR (20 mm proximal to the lesser trochanter) were associated with the presence of spot welds. Mild stress shielding occurred in 25 hips (31.3%), and no patient experienced severe stress shielding. All stems were fixed by bone on growth. The JHEQ and HHS significantly improved at the final assessment. Conclusion At the five-year follow-up, patients who received the Actis Total Hip System during THA had good radiographic and clinical outcomes.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials