ArticleMagnetic resonance in medicine2025
Phantom-based gradient waveform measurements with compensated variable-prephasing: Description and application to EPI at 7 T.
Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Phantom-based gradient waveform measurements with compensated variable-prephasing: Description and application to EPI at 7 T.Magnetic resonance in medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIntroducing compensated variable-prephasing (CVP), a phantom-based method for gradient waveform measurements. The technique is based on the variable-prephasing (VP) method, but takes into account the effects of all gradients involved in the measurement.
methodsWe conducted measurements of a trapezoidal test gradient and of an EPI readout gradient train with three approaches: VP, CVP, and fully compensated variable-prephasing (FCVP). We compared them to one another and to predictions based on the gradient system transfer function. Furthermore, we used the measured and predicted EPI gradients for trajectory corrections in phantom images on a 7 T scanner.
resultsThe VP gradient measurements are confounded by lingering oscillations of the prephasing gradients, which are compensated in the CVP and FCVP measurements. FCVP is vulnerable to a sign asymmetry in the gradient chain. However, the trajectories determined by all three methods resulted in comparably high EPI image quality.
conclusionWe present a new approach allowing for phantom-based gradient waveform measurements with high precision, which can be useful for trajectory corrections in non-Cartesian or single-shot imaging techniques. In our experimental setup, the proposed "compensated variable-prephasing" method provided the most reliable gradient measurements of the different techniques we compared.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.