Evidence map›Paper›PMID 39833920›Full record

ReviewJournal of cardiothoracic surgery2025

Accuracy of Freestyle Libre continuous glucose monitoring system in critically ill patients after cardiac surgery.

Junjun Gu, Zhimin Zhao, Haiyan Li, Bailing Li, Si Chen, Yingdan Cao, Ning Li, Xiaoying Lu

Abstract readReview
In one paragraph

Review in Journal of cardiothoracic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Junjun Gu *Department of Cardiovascular Surgery, The first Affiliated Hospital of Naval Medical University, Shanghai, 200433, China.
Zhimin Zhao *Department of Cardiovascular Surgery, The first Affiliated Hospital of Naval Medical University, Shanghai, 200433, China.
Haiyan LiDepartment of Vascular Surgery, The first Affiliated Hospital of Naval Medical University, Shanghai, 200433, China.
Bailing LiDepartment of Cardiovascular Surgery, The first Affiliated Hospital of Naval Medical University, Shanghai, 200433, China.
Si ChenDepartment of Cardiovascular Surgery, The first Affiliated Hospital of Naval Medical University, Shanghai, 200433, China.
Yingdan CaoDepartment of Cardiovascular Surgery, The first Affiliated Hospital of Naval Medical University, Shanghai, 200433, China.
Ning LiDepartment of Cardiovascular Surgery, The first Affiliated Hospital of Naval Medical University, Shanghai, 200433, China. lining@smmu.edu.cn.
Xiaoying LuDepartment of Cardiovascular Surgery, The first Affiliated Hospital of Naval Medical University, Shanghai, 200433, China. luxiaoyingjoy@163.com.

Funding

Nursing Discipline Youth Training Project of Naval Medical University 2022KYG23
6 · The paper itself

Abstract

backgroundHyperglycemia is an independent risk factor for perioperative complications and mortality after cardiac surgery. Freestyle Libre Continuous glucose monitor (CGM) is an interstitial glucose monitoring system, which has been proven to be stable and accurate in various disease. MATERIALS AND

methods86 patients with hyperglycemia after cardiac surgery between October 2021 and October 2022 in the cardiovascular ICU, were enrolled in this study. We evaluated systematic errors and numerical accuracy in blood glucose (BG) between two groups using Bland-Altman analysis and mean absolute relative difference (MARD). The clinical accuracy was assessed by consensus and Clarke error grid.

results435 paired sensor-reference values were enrolled between the Freestyle and venous BG. The MARD was 18.2% with the Bland-Altman standard bias of 31.87 mg/dL. 1851 paired values were enrolled between the Freestyle and arterial BG. The MARD was 21.5%, and the Bland-Altman standard bias was 41.45 mg/dL. 432 paired values were enrolled between the arterial and venous BG. The MARD was 8.4%, and the Bland-Altman standard bias was - 9.95 mg/dL.

conclusionsOur study demonstrated the relatively low accuracy of Freestyle Libre CGM for critical patients after cardiac surgery. The arterial blood gas glucose analysis acts as an effective tool to improve BG management.

Indexed as

Blood GlucoseCardiac Surgical ProceduresHyperglycemiaPostoperative ComplicationsAgedContinuous Glucose MonitoringCritical IllnessFemaleHumansMaleMiddle AgedMonitoring, PhysiologicBlood GlucoseAccuracyArterial blood gasCardiovascular intensive care unitContinuous glucose monitoringHyperglycemia

Identifiers

PMID39833920
PMCPMC11749162

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.