Evidence map›Paper›PMID 39831522›Full record

ArticleMagnetic resonance in medicine2025

Composite spin probes with adjustable oxygen sensitivity for pulse electron paramagnetic resonance imaging.

Irene Canavesi, Navin Viswakarma, Raman Khurana, Boris Epel, Periannan Kuppusamy, Mark David Pagel, Mrignayani Kotecha

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Reconfigurable animal bed-EPR resonator assembly for multimodal co-registration.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2026
    Article
  2. Computationally efficient 4D spectral-spatial EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Irene CanavesiOxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA.
Navin ViswakarmaOxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA.
Raman KhuranaOxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA.
Boris EpelOxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA.ORCID 0000-0002-1382-7029
Periannan KuppusamyDepartment of Radiology, Geisel School of Medicine at Dartmouth College, Lebanon, New Hampshire, USA.ORCID 0000-0002-3214-0660
Mark David PagelDepartment of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.ORCID 0000-0002-8109-3995
Mrignayani KotechaOxygen Measurement Core, O2M Technologies, LLC, Chicago, Illinois, USA.ORCID 0000-0003-2264-0247

Funding

Probes and Methods for Clinical OximetryR01EB004031 · NIBIB · OHIO STATE UNIVERSITY · PI KUPPUSAMY, PERIANNAN · 2004 to 2021
$7.1M
Multimodal Marker for imaging oximetry in radiotherapyR01CA269234 · NCI · DARTMOUTH COLLEGE · PI PERIANNAN KUPPUSAMY · 2023 to 2026
$3.0M
National Science Foundation 2028829NCI NIH HHS R01 CA269234NIBIB NIH HHS R01 EB004031
6 · The paper itself

Abstract

purposeSolid crystalline spin probes, such as lithium phthalocyanine (LiPc) and lithium octa-n-butoxynaphthalocyanine (LiNc-BuO), allow repeated oxygen measurement using electron paramagnetic resonance (EPR). Due to their short relaxation times, their use for pulse EPR oxygen imaging is limited. In this study, we developed and tested a new class of solid composite spin probes that modified the relaxation rates R

methodsThe composite probes were developed by embedding LiPc or LiNc-BuO with bonewax, beeswax, or petroleum jelly. All experiments were performed using a 25-mT EPR imager, JIVA-25®. A selected composite probe, LiPc-BW5 (LiPc + 5-times bonewax), was tested for its in vivo stability and robustness using oxygen-enhanced EPR oxygen imaging. As another application, a LiPc-BW5-based marker was tested to outline the SCC7 tumor in a C3H mouse.

resultsThe composite probes showed an increased oxygen measurement range compared with unaltered probes. The in vivo experiments with LiPc-BW5 showed the stability of the probes for repeated oxygen imaging up to 4 weeks of measurements. The in vivo pO

conclusionsWe developed a new class of robust and versatile solid composite probes with adjustable oxygen sensitivity that allows pO

Indexed as

OxygenSpin LabelsAnimalsElectron Spin Resonance SpectroscopyIndolesMiceOrganometallic CompoundsSensitivity and SpecificityIndoleslithium phthalocyanineOrganometallic CompoundsOxygenSpin Labelscrystalline probeshypoxiaLiPcpulse EPR oxygen imagingsolid probe oxygen imaging

Identifiers

PMID39831522
PMCPMC11893242

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.