Evidence map›Paper›PMID 39831516›Full record

ArticleAnatomical sciences education2025

Departing from standard practices: Strategic application of value engineering in the anatomy laboratory to enhance formaldehyde extraction using high-impact, low-cost, and low-maintenance solutions.

Jürgen Russ, Niels Hammer

Abstract read
In one paragraph

Article in Anatomical sciences education, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Jürgen RussFacility Management Services, Medical University of Graz, Graz, Austria.
Niels HammerDivision of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria.ORCID https://orcid.org/0000-0001-8230-9383

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study describes the process of developing a high-impact, low-cost, and low-maintenance air ventilation system for anatomy facilities. It employed the strategic application of Value Engineering (VE), assuring that the air ventilation system meets contemporary threshold limit values (TLVs) for formaldehyde in the working zone of dissection tables. A creative-innovative construction methodology was used, combining the Theory of Inventive Problem Solving (TRIZ/TIPS) and VE for an anatomy laboratory air ventilation concept. The TRIZ/TIPS aimed to resolve conflicts that impeded progress toward higher ideality, while VE aimed to develop alternative approaches to fulfill required functions at a minimal cost. The findings were first trialed in a mockup while dissecting human tissues embalmed with two protocols. The experimental results were validated by computational fluid dynamics simulations, and then followed by a pilot and commissioning phase once the physical installation of the dissection laboratory concluded. The findings demonstrate the superiority of the combined TRIZ/TIPS and VE approach in terms of air distribution and efficient formaldehyde extraction within the breathing zone. A formaldehyde exposition below 0.1 ppm, lowered air exchange rates, and system usability proved that the given third-generation ventilation system complies with contemporary TLVs and potential changes in user requirements. The third-generation ventilation system offers a cost-effective, high-impact, and low-maintenance solution for state-of-the-art air ventilation systems in the anatomy dissection laboratory. The underlying design approach ensured that formaldehyde levels in the laboratory meet the TLV and indoor air guideline values for formaldehyde exposure, at which current knowledge indicates no increased risk of cancer.

Indexed as

Air Pollution, IndoorAnatomyFormaldehydeLaboratoriesOccupational ExposureVentilationCadaverDissectionEmbalmingHumansFormaldehydedissection roomformaldehydelaminar flowREDESIGN approachtheory of inventive problem solvingworkplace safety

Identifiers

PMID39831516
PMCPMC11909000

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.