Evidence map›Paper›PMID 39830422›Full record

ArticleActa medica Philippina2024

RP-HPLC Method for Rhein Quantification in

Jade P Rodriguez

Abstract read
In one paragraph

Article in Acta medica Philippina, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Jade P RodriguezInstitute of Herbal Medicine, National Institutes of Health, University of the Philippines Manila.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: The aim of this study is to establish a Reversed Phase - High Performance Liquid Chromatographic (RP-HPLC) method for the quantification of Rhein from Methods: A Shimadzu system equipped with a C18 Column (150 x 4.6 mm, 5 μm) with an isocratic elution of Acetonitrile (solvent A) and 0.1% trifluoroacetic acid aqueous solution (solvent B) (Merck, 1.08178.0050) with a 55:45 ratio, respectively and a flow rate of 1.0 mL/min and sample injection of 10 μL detection was done at 230 nm. Standard solution of Rhein (Chengdu Biopurify) was prepared for method development. This study was validated using the guidelines set under "ICH Topic Q2 R2 or the Validation of Analytical Procedures". Procedures for linearity, precision, accuracy, limit of detection, and limit of quantitation were performed. Results: The retention time of Rhein standard was determined at 5.10 minutes. LOD and LOQ were determined to be 1.278 mcg/mL and 3.872 mcg/mL, respectively with good linearity (R2 ≥0.996) with a linear range of 2.5-20 ug/mL of the Rhein standard. The accuracy of the method was determined based on % recovery method and ranged from 94.75%-100.32% (intraday, n=3) with %RSD of 0.71. The intraday precision %RSD was 2.92 (n=6) while interday precision %RSD was 3.75 (n=3). The method was able to check the Rhein quantity among 10 samples of Conclusion: The method was found to be sensitive and accurate for the quantification of Rhein. The method was found to be useful for the quantification of the amount of Rhein and can be used as a Quality Control tool for the assessment of

Indexed as

Cassia fistulaHPLCKanya pistulamethod validationRhein

Identifiers

PMID39830422
PMCPMC11739522

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.