Scan/rescan reliability of magnetic resonance imaging (MRI).

Menekse Salar Barim, M Fehmi Capanoglu, Richard F Sesek, Sean Gallagher, Mark C Schall, Ronald J Beyers, Gerard A Davis

Abstract read
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Menekse Salar BarimDivision of Field Studies and Engineering (DFSE), Engineering and Physical Hazards Branch (EPHB), Human Factors and Ergonomics Team (HFET), National Institute of Occupational Safety and Health (NIOSH), 1090 Tusculum Avenue, Cincinnati, OH, 45226, USA. oih9@cdc.gov.
M Fehmi CapanogluDepartment of Industrial and Systems Engineering, Auburn University, 3301 Shelby Center, Auburn, AL, 36849-5346, USA.
Richard F SesekDepartment of Industrial and Systems Engineering, Auburn University, 3301 Shelby Center, Auburn, AL, 36849-5346, USA.
Sean GallagherDepartment of Industrial and Systems Engineering, Auburn University, 3301 Shelby Center, Auburn, AL, 36849-5346, USA.
Mark C SchallDepartment of Industrial and Systems Engineering, Auburn University, 3301 Shelby Center, Auburn, AL, 36849-5346, USA.
Ronald J BeyersMRI Research Center, Auburn University, Alabama, USA.
Gerard A DavisDepartment of Industrial and Systems Engineering, Auburn University, 3301 Shelby Center, Auburn, AL, 36849-5346, USA.

Funding

Intramural CDC HHS CC999999NIOSH CDC HHS #2T420H008436
6 · The paper itself

Abstract

backgroundMagnetic resonance imaging (MRI) is increasingly used to estimate the geometric dimensions of lower lumbar vertebrae. While MRI-based measurements have demonstrated good reliability with interclass correlation coefficients (ICCs) of 0.80 or higher, many evaluations focus solely on the comparison of identical MRI images. This approach primarily reflects analyst dexterity and does not assess the reliability of the entire process, including imaging and image selection.

objectiveTo evaluate the inter- and intra-rater reliability of the entire process of using MRI to measure biomechanically relevant lumbar spinal characteristics, incorporating imaging, image selection, and analysis.

methodsA dataset of 144 low-back MRI scans was analyzed. Reliability assessments were performed under different conditions: (1) identical scans rated by the same analyst at different times (intra-rater reliability) and (2) distinct scans of the same subject obtained by different MRI operators and analyzed by different analysts (inter-rater reliability). Mean absolute differences in measurements were calculated, and sources of variability, such as breathing artifacts, were noted.

resultsLarger discrepancies were observed when comparing distinct scans analyzed by different MRI operators and analysts. In the "worst-case" scenario, where both the MRI operator and analyst differed, a 4.05% mean absolute difference was noted for anterior endplate measurements. This was higher than the 2.76% difference observed when analysts re-rated their own scans after one month. Despite these discrepancies, the variability in measurements was relatively low and primarily attributed to factors like breathing artifacts.

conclusionThe process of using MRI to derive biomechanical measures, particularly for bony structures, demonstrates robust reliability. Variability in measurements is minimal even under challenging conditions, supporting the use of MRI for biomechanical assessments.

Indexed as

Lumbar VertebraeMagnetic Resonance ImagingAdultFemaleHumansMaleMiddle AgedObserver VariationReproducibility of ResultsMagnetic resonance imagingReliabilityRepeatabilityVertebral and intervertebral dimensions