ArticleNature communications2025
Quantum magnetometry of transient signals with a time resolution of 1.1 nanoseconds.
Article in Nature communications, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Multimodal scanning-probe quantum sensing of quantum materials.Nature materials · 2026Review
- Imaging of gate-controlled suppression of superconductivity via the Meissner effect.Nature communications · 2026Article
- Sensitivity Improvement via Differential Detection for Frequency-Locking Diamond Magnetometers.Micromachines · 2025Article
- Quantum magnetometry of transient signals with a time resolution of 1.1 nanoseconds.Nature communications · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Quantum magnetometers based on spin defects in solids enable sensitive imaging of various magnetic phenomena, such as ferro- and antiferromagnetism, superconductivity, and current-induced fields. Existing protocols primarily focus on static fields or narrow-band dynamical signals, and are optimized for high sensitivity rather than fast time resolution. Here, we report detection of fast signal transients, providing a perspective for investigating the rich dynamics of magnetic systems. We experimentally demonstrate our technique using a single nitrogen-vacancy (NV) center magnetometer at room temperature, reaching a best-effort time resolution of 1.1 ns, an instantaneous bandwidth of 0.9 GHz, and a time-of-flight precision better than 20 ps. The time resolution can be extended to the picosecond range by use of on-chip waveguides. At these speeds, NV quantum magnetometers will become competitive with time-resolved synchrotron X-ray techniques. Looking forward, adding fast temporal resolution to the spatial imaging capability further promotes single-spin probes as powerful research tools in spintronics, mesoscopic physics, and nanoscale device metrology.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.