Evidence map›Paper›PMID 39827102›Full record

ArticleBMC oral health2025

Biomechanical behavior of titanium, cobalt-chromium, zirconia, and PEEK frameworks in implant-supported prostheses: a dynamic finite element analysis.

Dilara Sahin Hazir, Irem Sozen Yanik, M Baris Guncu, R Senay Canay

Abstract read
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Dilara Sahin HazirDepartment of Prosthodontics, Faculty of Dentistry, Hacettepe University, 06230, Sıhhiye/Altındağ, Ankara, Turkey.ORCID 0000-0002-4305-0257
Irem Sozen YanikDepartment of Prosthodontics, Faculty of Dentistry, Hacettepe University, 06230, Sıhhiye/Altındağ, Ankara, Turkey. iremsozen@hacettepe.edu.tr.ORCID 0000-0002-9420-7787
M Baris GuncuDepartment of Prosthodontics, Faculty of Dentistry, Hacettepe University, 06230, Sıhhiye/Altındağ, Ankara, Turkey.ORCID 0000-0001-6109-2218
R Senay CanayDepartment of Prosthodontics, Faculty of Dentistry, Hacettepe University, 06230, Sıhhiye/Altındağ, Ankara, Turkey.ORCID 0000-0003-0485-361X

Funding

The Scientific and Technological Research Council of Turkey (TUBITAK) ARDEB 1002 121S213
6 · The paper itself

Abstract

backgroundThe mechanical properties of framework materials significantly influence stress distribution and the long-term success of implant-supported prostheses. Although titanium, cobalt-chromium, zirconia, and polyether ether ketone (PEEK) are widely used, their biomechanical performance under dynamic loading conditions remains insufficiently investigated. This study aimed to evaluate the biomechanical behavior of four framework materials with different Young's modulus using dynamic finite element stress analysis.

methodsA 3D edentulous maxillary model was extracted from a computer tomography (CT) database. Bone level implants with conical connection designs were placed in the anterior (canine) and posterior (first molar) areas. Anterior implants were parallel, yet posterior implants were inclined distally by 30 degrees. According to the framework material, four groups were formed: cobalt-chromium (Co-Cr), zirconia (Zr), titanium (Ti), and polyether ether ketone (PEEK). For each framework material, twelve separate models of analysis were created by applying force in three different orientations. Dynamic forces were employed to replicate the chewing process. Principal and von Mises stresses were measured and evaluated.

resultsThe PEEK framework exhibited the highest maximum von Mises stress values (372.55 MPa) on the abutment and the highest maximum principle stress values (59.27 MPa) in the cortical bone. The Co-Cr framework had the lowest minimum principle stress (3.98 MPa) in the trabecular bone. The displacements of the Co-Cr, Zr, Ti, and PEEK frameworks were 0.15 mm, 0.15 mm, 0.17 mm, and 0.35 mm, respectively.

conclusionFrameworks having a greater Young's modulus are less susceptible to deformation.

Indexed as

Chromium AlloysDental MaterialsDental Prosthesis, Implant-SupportedKetonesPolyethylene GlycolsTitaniumZirconiumBenzophenonesBiomechanical PhenomenaDental Stress AnalysisElastic ModulusFinite Element AnalysisHumansPolymersBenzophenonesChromium AlloysDental MaterialsKetonespolyetheretherketonePolyethylene GlycolsPolymersTitaniumZirconiumzirconium oxideDental prosthesisEdentulous maxillaFinite element analysisImplantYoung's modulus

Identifiers

PMID39827102
PMCPMC11748589

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.