Evidence map›Paper›PMID 39825302›Full record

ArticleBMC oral health2025

Retention of CAD-CAM locator retentive attachment insert in mandibular implant overdenture.

Mai Hassan Diab, Medhat Sameh Abdelaziz, Mohamed Hatem Kamal Eldin

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mai Hassan DiabRemovable Prosthodontics Department, Faculty of Dentistry, October 6 University, Giza, Egypt.
Medhat Sameh AbdelazizFaculty of Oral and Dental Medicine, Prosthodontics Department, Future University in Egypt, Cairo, Egypt. medhat.abdelaziz@fue.edu.eg.ORCID 0000-0002-9646-2343
Mohamed Hatem Kamal EldinRemovable Prosthodontics Department, Faculty of Dentistry, October 6 University, Giza, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe continuous development in digital prosthodontics allowed the customization of attachments and retentive inserts which offers an easy and cheap solution for regular maintenance of locator overdentures during daily practice. The present study compared the change in retention values of the fully digitally manufactured custom-made locator attachment retentive insert with the ready-made ones after insertion, removal, and masticatory cycles.

methodsA complete denture was constructed over a mandibular edentulous epoxy model. Two implants were inserted into the model between the laterals and canines following the prosthetically driven implant protocol. Locator retentive attachment inserts were digitally designed using free-form modeling software and milled from PEEK (Poly Ether Ether Ketone). After the pick-up of the ready- and custom-made retentive inserts, an insertion, removal, and masticatory cycles test simulating 1 year of patient usage was performed. The change in retention values was recorded at baseline, 6 months, and after one year of simulated clinical use. An independent sample t-test was used to compare the data between the two studied groups.

resultsThere were statistically significant differences in retention values between the custom-made and ready-made locator inserts at baseline and after 6 months. (p = 0.001*). On the other hand, there was no significant difference in retention after 1 year of simulated use. (p = 0.083, NS)

conclusionsThe custom-made milled locator retentive attachment insert can be used as an alternative to the ready-made one due to their comparable retention values after 1 year of simulated use.

Indexed as

Computer-Aided DesignDental Prosthesis, Implant-SupportedDenture, Complete, LowerDenture DesignDenture, OverlayDenture RetentionBenzophenonesDental Prosthesis DesignHumansKetonesMandibleMasticationPolymersBenzophenonesKetonespolyetheretherketonePolymersAided designComputerDental implantationDenture precision attachmentDenture retention

Identifiers

PMID39825302
PMCPMC11742198

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials