ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2025
Anatomical investigation of safety determining factors for keyhole drilling trajectories for robotic cochlear implant surgery.
Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06890546 (Effect of Nigella Sativa Oil Supplementation and Dietary Intervention on Lipid Profile in Overweight Adults with Hyperlipidemia), which is not on this map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Effect of Nigella Sativa Oil Supplementation and Dietary Intervention on Lipid Profile in Overweight Adults with Hyperlipidemia: a Randomized Controlled Clinical Trial
Who cites it
2 citing papers in PubMed.
- Feasibility of Minimally Invasive Robot-Assisted Retrofacial Access to the Stapedius Muscle for Applications in Objective Cochlear Implant Fitting: A Cadaveric Study.The international journal of medical robotics + computer assisted surgery : MRCAS · 2026Article
- [Skull base surgery-where do we stand?]HNO · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeCochlear implants (CI) are the most successful bioprosthesis in medicine probably due to the tonotopic anatomy of the auditory pathway and of course the brain plasticity. Correct placement of the CI arrays, respecting the inner ear anatomy are therefore important. The ideal trajectory to insert a cochlear implant array is defined by an entrance through the round window membrane and continues as long as possible parallel to the basal turn of the cochlea. Image-guided surgery can directly drill with a robotic arm through the mastoid and execute an exact drilling of this precalculated most ideal trajectory. Here, we aim to identify critical anatomical structures determining the safest keyhole drilling trajectory by comparing easy and difficult CI surgeries performed with the HEARO Procedure: a robotic tool for image-guided surgery.
methodsCone-beam computed tomography images of patients who underwent robot-assisted cochlear implantation surgery (RACIS) were included. Three of 25 cases had to be converted to conventional surgery because of the current safety mitigations based on anatomical distance. Radiological images in DICOM format were transferred to dedicated software (OTOPLAN® Cascination GMHB Bern Switzerland) for analyses. Surgical segmentation and previously planned trajectories were analyzed for these 25 cases by comparing cochlear sizes, facial recess sizes, round window sizes, and trajectory angles. In addition, facial recess angle, and cochlear orientation angles were measured with RadiAnt DICOM Viewer (Medixant, Pozan, Poland).
resultsFacial recess size, facial recess angle, and distance between the facial nerve and safe trajectory were smaller in patient who converted from robotic surgery to conventional. A significant positive correlation existed between basal turn angle and in-plane angle (p = 0.001, r = 0.859). In addition, there was a significant negative correlation between the basal turn length and the last electrode insertion depth degree (p = 0.007, r = 0.545).
conclusionIn our robotic surgery cases, we demonstrate that the limiting factors of anatomical relationships are constituted by the dimensions of the facial recess and the cochlear orientation. The findings of this study are considered to be a reference for future studies in achieving collision-free trajectory planning in robotic-assisted cochlear implant surgery.