Evidence map›Paper›PMID 39825199›Full record

ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2025

Robot-assisted vs. manual cochlear implant electrode array insertion in four children.

Vittoria Sykopetrites, Eleonora Sica, Raffaella Moalli, Davide Cocozza, Sergio Razza, Eliana Cristofari

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Vittoria SykopetritesDepartment of Audiovestibology, ASST dei Sette Laghi, Via Lazio, 21100, Varese, VA, Italy. v.sykopetrites@gmail.com.ORCID http://orcid.org/0000-0002-2439-1021
Eleonora SicaDepartment of Audiovestibology, ASST dei Sette Laghi, Via Lazio, 21100, Varese, VA, Italy.
Raffaella MoalliDepartment of Audiovestibology, ASST dei Sette Laghi, Via Lazio, 21100, Varese, VA, Italy.
Davide CocozzaDepartment of Audiovestibology, ASST dei Sette Laghi, Via Lazio, 21100, Varese, VA, Italy.
Sergio RazzaDepartment of Audiovestibology, ASST dei Sette Laghi, Via Lazio, 21100, Varese, VA, Italy.
Eliana CristofariDepartment of Audiovestibology, ASST dei Sette Laghi, Via Lazio, 21100, Varese, VA, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeEvaluate the feasibility and safety of a robotic electrode insertion in pediatric cochlear implantation and compare the results with manually inserted electrodes in the same subject.

methodsRetrospective case series review of four children who underwent bilateral cochlear implantation with the same array: on one side, the array was inserted using the robot, while on the other side the array was inserted manually. Behavioural and electrophysiological measures were compared.

resultsThe duration of surgery when the robot was adopted was significantly longer than when a manual insertion was performed (161.15 ± 27.59 minutes vs. 122.6 ± 37.71 min, paired t-test: p = 0.029). Moreover, robotic electrode insertion was significantly slower (average insertion speed 0.3 mm/second vs. 0.52 ± 0.17 mm/s, paired t-test: p = 0.0055). On radiologic examination, none of the arrays was misplaced. Impedance, both at activation and at one year of cochlear implant use, was significantly lower on the robotic side in monopolar mode compared to the manual side (mean 9.64 ± 2.41kΩ and 9.97 ± 1.39 kΩ vs. 10.43 ± 2.69 kΩ and 10.94 ± 1.11 kΩ, paired t test, p = 0.0251 and p = 0.0061, respectively). Both the threshold stimulation level and the most comfortable loud stimulation level were significantly lower in the robotic inserted ear compared to the manually inserted ear (mean 108.1 ± 5.98 and 169 ± 4.84 vs. 112.1 ± 7.43 and 172.7 ± 6.83, respectively, paired t test p < 0.0001).

conclusionsAlthough we present a small group of cases, our results show how robot-based array insertion is associated with lower impedance and stimulation levels compared to manually inserted arrays.

Indexed as

Cochlear ImplantationCochlear ImplantsRobotic Surgical ProceduresChildChild, PreschoolElectrodes, ImplantedFeasibility StudiesFemaleHumansInfantMaleOperative TimeRetrospective StudiesCochlear implantImpedanceInsertionPediatric cochlear implantRobot

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.